4
Turn off cold water shut-off valve then turn on
the kitchen faucet and allow all water to drain
from line.
SETTING CAPACITY AND TDS FUNCTION
NOTE: Set capacity and TDS function before starting installation.
NOTE: To access the dip switches for setting capacity and TDS function,
open the control box by removing the three screws in the rear cover.
Find the dip switches on the front of the circuit board.
SW2 and SW3 set the time and capacity for the filter reminder.
SW2: OFF = 500 gallons
ON = 1000 gallons
SW3: OFF = 180 days
ON = 365 days
SW1 Enables/Disables the TDS function (Enable only for RO systems).
The system will measure the difference between the feed and product
water to determine if the RO is working.
SW1: OFF = Disabled
ON = Enabled
SW6 is used for production testing and should be left in the off position.
INSTALLATION
NOTE: Refer to the manual provided with your filter/RO for installation
instructions
specific to that system.
NOTE: Some installations may require adapters and fittings not included with
the product. Review the manual and your installation before beginning.
NOTE: Consult your local plumbing codes and install accordingly.
Disconnect the cold water line from the cold water
shut-off valve.
NOTE:
If rigid plumbing pipe (metal or plastic)
is used, you may need to shorten the pipe using
a hacksaw or pipe cutter to accommodate the
control box.
SW6
SW3
SW2
SW1
ON