2
PRECAUTIONS
WARNING: Follow all precautions indicated in the manual provided with the water treatment system.
WARNING: For systems using a booster or distribution pump, the pressure of the treated water cannot
exceed the pressure of the cold water supply.
CAUTION: Control box must be protected against freezing temperatures, frost, snow, sleet, and ice.
Exposure to these can produce cracks and product failures.
CAUTION: This product has a limited service life. We recommend that a record be kept regarding
the date of install and any other performed maintenance. Because of the product’s limited service
life and to prevent costly repairs or possible water damage, we strongly recommend that the control
box be replaced every ten years.
WARNING: For cold water use only. Do not use on hot water line.
• After prolonged periods of non-use (such as during a vacation) it is recommended that the
system be flushed thoroughly. Let the filtered water run for
5–6
minutes before using.
• The US-CL estimates filter life based on flow and time. Changes in taste, odor, color,
and/or flow of the filtered water could indicate that the filter(s) should be replaced.
• Make certain that installation complies with all state and local laws and regulations.
PARTS
INCLUDED:
• Remote Button
• Control Box
• Battery Box
•
3/8" x 1/4"
Tube Adapters
• Mounting Screws
• Air Gap
SPECIFICATIONS
Pressure Range:
30 –120 psi (207–827 kPa)
Temperature Range:
40 –100°
F (4.4 – 37.7
°
C)
TOOLS & MATERIALS REQUIRED
• C Batteries x
4
• AAA Batteries x
2
• Screwdriver
• Adjustable Wrench
• Towels
• Pan or Bucket
English