5
Tighten the control box to the cold water shut-off
valve as shown. Tighten the lower end of cold water
line onto the top of the control box.
NOTE: The control box must be in a
vertical position.
NOTE: If space does not allow for mounting the
control box onto the valve, it can be alternatively
hung on a wall when using the holes on the back
and a flex connection (purchased separately).
Connect the inlet on the RO/Filter system to the
blue port marked "RO/Filter
>
." Wet the end of
the plastic tubing with water and push it into the
quick connect fitting adapter approximately
5/8˝
until it stops.
NOTE: This is the line that would normally come
from the water supply adapter.
NOTE: Use one of the supplied adapters if your
system uses
1/4"
tube.
Connect the outlet on the RO/Filter system to the
white port marked "RO/Filter
<
." Wet the end of
the plastic tubing with water and push it into the
quick connect fitting adapter approximately
5/8"
until it stops.
NOTE: This is the line that would normally go to
your dedicated faucet.
NOTE: Use one of the supplied adapters if your
system uses a
1/4"
tube.
NOTE: Connect the tank and/or post filter in this