background image

73

01023052

Parts List

16" and 18" Brine 

System

1

5

4

3

2

Item

Part No.

Description

-

01018705

Brine System, 250 lb

-

01018715

Brine System, 375 lb

1

01018709

Replacement Tank, 250 lb

01018716

Replacement Tank, 375 lb

2

01018704

Cover, 250 lb

01018717

Cover, 375 lb

3

01018707

Salt Plate, 250 lb

01018713

Salt Plate, 375 lb

4

01018707

Brine Chamber, 250 lb & 375 lb

5

01018706

Brine Valve

Summary of Contents for HE Twin Water Softener

Page 1: ...Culligan High Efficiency Twin Automatic Water Softeners Owners Guide ...

Page 2: ... must accept all interference received including interference that may cause undesired operation This equipment complies with Part 15 of the FCC rules Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority ...

Page 3: ...ply Usage and Service 42 Care and Cleaning of Your Water Conditioner 43 Cleaning Out the Salt Storage Tank 44 Sanitizing Procedure 45 Things to Check Before You Call for Service 46 Error Codes 47 When and How to Bypass Your Water Softener 48 Performance Data Sheets 49 California Department of Public Health Certificates 61 mportant Data on Your Water Softener 65 Electrical Schematic 66 Parts Lists ...

Page 4: ... the unit before removing the timer mechanism or cover plates The CAUTION and WARNING paragraphs are not meant to cover all possible conditions and situations that may occur Understand that common sense caution and careful attention are conditions which cannot be built into the equipment These MUST be supplied by the personnel installing operating or maintaining the system Be sure to check and fol...

Page 5: ... your first experience having soft conditioned water in your home you ll be amazed at the marvel ous difference it makes We promise that you ll never want to be without it again Congratulations too on selecting one of the first family of water conditioners in the prestigious Culligan High Efficiency Water Softeners With Culligan s many years of knowledge and experience in water treat ment you can ...

Page 6: ...city 375 lb 375 lb 375 lb 600 lb Rated Service Flow Pres sure Drop 9 0 gpm 11 psi 9 4 gpm 12 psi 10 0 gpm 10 psi 10 6 gpm 11 psi Auxiliary Flow Rate4 10 8 gpm 15 psi 11 0 gpm 15 psi 12 6 gpm 15 psi 12 8 gpm 15 psi Total Hardness Maximum 75 gpg 99 gpg 99 gpg 99 gpg Total Iron Maximum 5 ppm Hardness to Iron Ratio Minimum 8 gpg to 1 ppm Operating Pressure 20 125 psi 138 862 kPa Operating Pressure Can...

Page 7: ... Iron Ratio Minimum 8 gpg to 1 ppm Operating Pressure 20 125 psi 138 862 kPa Operating Pressure Canada 20 90 psi 138 621 kPa Operating Temperature 33 120 F 0 49 C Electrical Requirements 24V 60 Hz Electrical Power Consumption Min Max 8 4 watts 21 6 watts Drain Flow Maximum6 2 2 gpm 2 3 gpm Recharge Time Average7 Recharge Water 68 minutes 57 minutes Consumption Average7 33 gallons 35 gallons 1 The ...

Page 8: ... Soft water promotes sanitation because no greasy hard water film can form to collect or harbor bacteria Easier Housekeeping Gleaming Fixtures You ll be amazed at the marvelous difference Just a swish of the cloth and the bathtub or shower and fixtures are clean and sparkling Imagine no scouring No hard water scum to cause rings streaks spots and stains To keep their gleaming luster simply wipe fi...

Page 9: ...ate Iron Also called ferric or colloidal iron This type of iron is an undissolved par ticle of iron A softener will remove larger particles but they may not be washed out in regen eration effectively and will eventually foul the ion exchange resin A filtering treatment will be required to remove this type of iron 3 Organic Bound Iron This type of iron is strongly attached to an organic compound in...

Page 10: ...n be dis solved to provide the brine solution that will be needed for the next regeneration cycle B The Mineral Tank The Mineral Tank contains the Cullex resin column Cullsan underbedding and an outlet manifold the Culligan Municipal also includes carbon media for chlorine taste odor reduction The number of gallons of hard water that can be softened by the Cullex resin column before it needs regen...

Page 11: ...of the water softener or filters and allows for remote control It can be located up to 200 feet away from the softener depending upon building construction materials The wireless remote displays information about softener performance problems days of salt remaining and allows remote control for regeneration The wireless remote control is designed to communicate at 915 MHz and to work without inter...

Page 12: ...low regeneration Proportional Brining The control monitors your softened water usage making only enough brine to regenerate that part of the resin bed that has been exhausted In this way the amount of salt used relates directly to the amount of softened water used making it more efficient and cost effective Proportional brining can only be used with upflow regeneration The Aqua Sensor or meter can...

Page 13: ...e and chamber Tools and Materials The following tools and supplies will be needed depending on installation method NOTE Check and comply with your state and local codes You must follow these guidelines For installations in Massachusetts Massachusetts Plumbing Code 248 CMR shall be adhered to Consult your licensed plumber for installation of this system This system and its installation must comply ...

Page 14: ...essure switch if necessary CAUTION Do not use where the water is microbiologically unsafe or with water of unknown quality adequate disinfection before or after the unit CAUTION The use of a pressure reducing valve may limit the flow of water in the household Temperature Do not install the unit where it might freeze or next to a water heater or furnace or in direct sunlight Outdoor installation is...

Page 15: ...g in transformer are provided The customer should provide a recepta cle preferably one not controlled by a switch that can be turned off accidentally Observe local electrical codes NOTE The softener works on 24 Volt 60 Hz electrical power only Be sure to use the included transformer Be sure the electrical outlet and transformer are in an inside location to protect from moisture Properly ground to ...

Page 16: ...e Tank Assembly 9 and 10 tanks are filled with media at the factory 1 Before the unit can be connected to the plumbing you must insert the manifold and load the media into the tank for 12 and 14 units CAUTION Do not lay the tank down unless a suitable lifting device is available Personal injury and damage to the unit can result if dropped Position the Mineral Tank s Determine the location for the ...

Page 17: ...he tank CAUTION DO NOT allow the outlet manifold to move when loading the media The manifold must remain vertical to ensure a good seal at the gasket Rap the tank near the bottom with a rubber mallet to level the sand 6 Load the tank with the Cullex ion exchange resin Leveling is not required 7 Remove the funnel 8 Install the inlet strainer making sure to thread the strainer until it bottoms out o...

Page 18: ...dure on page Mount the Control Valve See Figure 4 for an illustration on mounting the control valve to the tank 1 Assemble the O rings located in the parts pack to the tank adapter 2 The valve adapter O ring sits on the first step on the adapter See Figure 5 NOTE Do not push the top O ring down to the flange surface on the adapter NOTE The larger of the two O rings in the parts should be positione...

Page 19: ...ing the backwash flow control eductor nozzle and eductor throat Unit Backwash Flow Nozzle Throat Brine Refill Flow 9 Upflow 2 5 3 1 gpm 2 Brown Blue Gray 0 45 gpm 10 Upflow 2 5 3 1 gpm 2 Brown Blue White 0 45 gpm 9 Downflow 2 5 3 1 gpm 2 Brown Blue Light Brown 0 45 gpm 10 Downflow 2 5 3 1 gpm 2 Brown Beige Light Brown 0 45 gpm 12 Downflow 3 0 3 2 gpm 3 Green Beige Light Brown 0 8 gpm 14 Downflow 5...

Page 20: ...plications the arrow faces up for upflow proportional brining regeneration applications Nozzle Throat Eductor Cap Screen Clip Figure 6 Removing the eductor nozzle and throat Backwash Flow Control Replacement Refer to Figure 7 through Figure 9 Table 2 and instructions below to replace the backwash flow control 1 Remove the cover by releasing the cover fastener from the control valve See Figure 7 an...

Page 21: ...rine line is connected re attach the cover Refer to the below instructions and Figure 10 through Figure 12 1 Insert the two pins on the top of the cover into the two holes on top of the frame the cover should be slightly angled See Figure 10 2 Rotate the cover downward inserting the two pins on the side of the cover into the two holes on side of the frame See Figure 11 3 Attach the cover fastener ...

Page 22: ...18 01023052 Figure 10 Cover fastener clip Figure 11 Reattaching the HE softener cover A Cover Fastener Push down into place Figure 12 Reattaching the cover fastener ...

Page 23: ...ced System Setup to update the Dial a Softness setting Plumbing Connections Shipped with each softener is a Culligan bypass valve which is used to connect the softener to the plumbing system The bypass allows the softener to be isolated from the water service line if service is necessary while still providing water to the home The bypass valve can be directly plumbed into the system or can be conn...

Page 24: ...he interconnecting pipe is connected to the outlet of Control 1 and the inlet of Control 2 Assembly Pin Connected to Flow Meter on Valve 2 Bypass Coupling Brine Connection Flow Meter Interconnecting Pipe MAIN VALVE 1 VALVE 2 Brine Connection Coupling Bypass Connected to Circuit Board on Valve 1 Figure 14 Bypass valve assembly NOTE If the ground from the electrical panel or breaker box to the water...

Page 25: ...to Table 3 for drain line length and height limitations under the applicable tank size 1 Remove 1 2 pipe clamp from the small parts pack included with the control 2 Route a length of 1 2 drain line from the drain elbow to the drain 3 Fasten the drain line to the elbow with the clamp 4 Secure the drain line to prevent its movement during regeneration When discharging into a sink or open floor drain...

Page 26: ...e 3 Height of Discharge Above Floor Level Operating Brine System Assembly Duplex Models Models using a common brine tank should be assembled as follows 1 Cut off approximately two inches of brine tubing then attach the tubing to the brine safety valve See Figure 17 2 Connect the center leg of the duplex tee provided in the small parts pack to the other end of the tubing 3 Connect the brine line tu...

Page 27: ... 1 Remove nut retaining brine valve to brine chamber 2 Lift the brine valve from the brine chamber 3 Find the correct A dimension from Appendix A in the HE Twin Softener Installation Operation manual PN 01023053 4 Set the distance from the top of the filter screen to the base of the float accordingly The slight difference in height when the float is pulled up or down is negligible 5 Re install int...

Page 28: ...des 1 Remove the electrical enclosure from the control valve First remove the electrical enclosure screw and then gently remove the enclosure from the control Refer to Figure 19 and below instructions 24 Volt Power Cord Flow Meter Wire Harness Aqua Sensor Wire Harness and 2 5 Volt Power Cord Flow Meter Harness Motor Cable and Gearbox Position Cable from Control 2 Electrical Enclosure Screw Figure ...

Page 29: ...pply wire harness and the Aqua Sensor sensor probe wire harness through the third hole on the enclosure NOTE The wire connectors must be connected to the circuit board properly The wires must exit the plug in connector opposite of the raised white base of the circuit board connector Failure to properly connect any of the connectors will result in a malfunction of the circuit board operation 24 Vol...

Page 30: ... parts pack It has two spade terminals on one end of the cable and circuit board connector on the other end b The power connection to the circuit board should be inserted INSIDE the controller The spade terminals should be connected to the transformer c Discard the dummy connector on the 2 5 VAC circuit board pins d Connect the Aqua Sensor power cord to the 2 5 VAC pins on the circuit board e Conn...

Page 31: ... the terminals to circuit board are correct before applying power to the control 24V power must not be applied to the 2 5 VAC terminals CAUTION Connecting 24V to the 2 5 VAC connection on the circuit board will damage the circuit board 12 Insert the circuit board back into the enclosure a Angle the circuit board opposite the front enclosure and into the support bracket on the side of the enclosure...

Page 32: ...Align slot on frame with edge of circuit board in the enclosure Insert screw on enclosure into holder on control valve Align slot on frame with edge of circuit board in the enclosure Align slot on frame with edge of circuit board in the enclosure Figure 24 Attaching enclosure cover to control valve c Screw the enclosure on the control d Attach the strain relief fittings to the Aqua Sensor probe 2 ...

Page 33: ...ew screen or accepts a changed setting CANCEL or X button returns to the previous screen or cancels a changed setting NOTE Hold down or to quickly scroll through the setting without repeatedly pressing the button Softening JAN 01 12 11 19A 1 This is the HOME SCREEN Press any button except to advance to the MAIN MENU SCREEN 1 INFORMATION 2 MANUAL MODE 2 This is the MAIN MENU SCREEN The symbol indic...

Page 34: ...ss again to select the next available value BYPASS MANUAL MODE REGEN NOW 7 Press to cancel the changed setting and revert to the default set ting The screen displays the default setting MANUAL MODE BYPASS 8 Press to accept the changed value If the setting values are dis played the symbol no longer appears next to the value 1 INFORMATION 2 MANUAL MODE 9 The screen then returns to the MAIN MENU Pres...

Page 35: ...r be reported to Culligan on the IQR form Firmware Version FWR LT21 MON DD YEAR The screen displays the firmware version and date installed for this Smart Controller Press to display the month setup screen Set Month Jan Dec SET MONTH JAN The screen displays the month setting Press to accept the information displayed and view the next setting or Press or to change the setting and advance to the nex...

Page 36: ... the next setup screen or press to change the setting Press to change the minutes in this example from 0 to 20 Press to accept the selected hour and advance to the next setting UNIT TYPE Unit Type Softener Filter or Resin Carbon UNIT TYPE SOFTENER The screen displays the unit type setting Press to accept the default set ting softener and advance to the next setting VALVE TYPE Valve Type HE 1 HE 1 ...

Page 37: ...ge the value and begin initialization Completed First Time Setup Initializing JAN 01 12 12 01P When the setup is complete the circuit board microprocessor automat ically calculates softener capacity The screen displays the initializing status and the current date and time and then transitions to the home screen SOFTENING JAN 01 12 12 01P The screen displays the current state the display alternates...

Page 38: ...een displays the month setting Press or and then to change the setting Set Day SET DAY 1 1 31 4 The screen displays the day setting Press or and then to change the setting Set Year SET YEAR 2012 2009 2030 5 The screen displays the year setting Press or and then to change the setting Set Clock Type CLOCK TYPE 12 HR 12 HR 24 HR 6 The screen displays the clock type setting Press or and then to change...

Page 39: ...NG YES Yes No 9 The screen displays the Daylight Savings Time setting Press or and then to change the setting 2 MANUAL MODE 3 SET DATE TIME 10 The screen displays the main menu Press to save the changes and initialize the system SOFTENING JAN 01 12 12 01P 11 The screen displays the home screen ...

Page 40: ...ftening capacity remaining displayed as a percentage of the total capacity During manually initiated regeneration assume 0 percent re maining capacity Press to select the next informa tion screen REMAIN CAPACITY 740 GAL 0 no limit 5 The screen displays the softening capacity remaining measured in gallons liters Press to see the next in formation screen CURRENT FLOWRATE 0 0 GPM 0 no limit 6 The scr...

Page 41: ...tion screen EXT FILT CAP REM 20000 GAL 0 no limit 11 If an external filter is used the screen displays the re maining capacity of the filter When the remaining capacity reaches zero the system triggers the External Filter Alarm Press to return to the main menu 1 INFORMATION 2 MANUAL MODE 12 The screen displays the main menu Press to exit to the home screen SOFTENING JAN 01 12 12 01P 13 The screen ...

Page 42: ...ime based on Day of Week Regeneration setting Follow either procedure to bypass the softener or to initiate a manual regeneration or automatically by pass the softener at the control valve or the remote display Delayed Regeneration Screen Display Range Setting Description SOFTENING JAN 01 12 12 01P N A 1 From the HOME screen press and hold for at least five 5 seconds REGEN TONITE JAN 01 12 12 01P ...

Page 43: ...REGEN OFF specifies the softener will not regenerate REGEN TONITE specifies that the softener will regener ate that night at 2 00 a m or at the preset regeneration time The screen displays two status messages SOFT ENING and REGEN TONITE BYPASS specifies a preset softener bypass time Press to select the total time the softener is in the bypass state MANUAL BYPASS OFF Off 30 60 90 120 180 Manual Byp...

Page 44: ... on cycling the control through its posi tions 10 When in the BACKWASH position slowly rotate the bypass to the soft water position until water flows 11 Allow the tank to fill slowly until water flows from the drain line 12 When flow to drain is established open the bypass fully Watch the drain line discharge for signs of resin If signs of resin particles appear reduce the flow Increase the flow a...

Page 45: ...ntil water flows 12 Continue BACKWASH until the drain effluent is clear and the Aqua Sensor probe is placed in the resin bed at least 10 minutes use a white foam coffee cup to occasionally collect a sample of backwash water the stark white of the cup will show the presence of color throw and resin fines 13 Continue or repeat the BACKWASH cycle if needed 14 After the backwash water runs clear step ...

Page 46: ...e compartment will require less frequent clean out but you must check more frequently for bridging Regardless of what type of salt is used we recommend Culligan Brand Salt as suggested by your Culli gan Dealer He or she is the expert and can provide you with the best product for your Culligan Water Conditioner Automatic Salt Delivery Service Ask your Culligan Dealer for details about salt delivery...

Page 47: ...rest Culligan dealer call 800 285 5442 Recommended Preventative Maintenance Inspection Schedule The Culligan High Efficiency household water softener has been designed to provide a good consistent service life Routinely inspecting the system may help avoid potentially costly breakdowns related to circumstances outside of the control of the dealer and or user Component Suggested Inspection Frequenc...

Page 48: ...salt remaining in the tank remove it and place it in a clean container 4 Using the scoop dig out and discard as much remaining salt water and debris as possible 5 Remove the brine valve chamber by removing the screws on either side of the salt tank 6 Remove the salt plate at the bottom of the brine tank 7 Lay the salt tank on its side and direct a brisk stream of water from your garden hose to its...

Page 49: ...ch and common iron control chemicals may generate toxic fumes when mixed If the unit uses Culligan Sofner gard or other compounds containing sodium hydrosulfite sodium bisulfite or any other reducing agent disconnect the device feeding the chemical s and manually regenerate the unit before sanitizing Do not use this procedure if the softener salt contains iron control additives 1 Remove the brine ...

Page 50: ...disrupt your soften er s regeneration schedule by causing the timer to run off schedule Reset the timer to the correct time of day Bypass Valves Check to see if they are in the proper position Cul Flo Valv Bypass if used should be in the Service position see page 21 If hand valves are used see that inlet and outlet valve are opened and that the bypass valve is closed No Water If you aren t getting...

Page 51: ...ges Replace Ext Filt Total gallons through the secondary filter i e Big Blue filter has exceeded the specified ca pacity of the Big Blue Replace optional filter cartridge Reset the external filter me dia life at Main Menu Accessories Ext Filter menu Check Brine Tank Aqua Sensor did not detect brine during the re generation cycle Check brine tank and add salt if necessary Check Z ratio of the Aqua ...

Page 52: ... recharge Bypass Valve In the back of Culligan water softener is a Cul Flo Valv Bypass valve To bypass the unit turn the blue knob clockwise To return to softened water service turn the blue knob counter clockwise Figure 25 Bypass valve Bypassed To BYPASS turn the blue knob clockwise see directional arrow on end of knob until the knob stops as shown in Figure 25 DO NOT OVERTIGHTEN About 1 1 4 Figu...

Page 53: ... certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness cal cium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also complies with specific performance specifications intended to minimize the amount of regenerant brine and water used in its ...

Page 54: ...ocal Culligan dealer The Culligan High Efficiency Twin 9 Water Softeners with Aqua Sensor Sensing Device are tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also compli...

Page 55: ...n dealer The Culligan High Efficiency Twin 10 Water Softeners with Soft Minder Meter are tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness cal cium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also complies with specific pe...

Page 56: ...ulligan dealer The Culligan High Efficiency Twin 10 Water Softeners with Aqua Sensor Sensing Device are tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also complies wi...

Page 57: ...ested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also complies with specific performance specifications intended to minimize the amount of regenerant brine and water used...

Page 58: ...local Culligan dealer The Culligan High Efficiency Twin 9 Water Softeners with Aqua Sensor Sensing Device are tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also compl...

Page 59: ... Culligan dealer The Culligan High Efficiency Twin 10 Water Softeners with Soft Minder Meter are tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also complies with spec...

Page 60: ...local Culligan dealer The Culligan High Efficiency Twin 10 Water Softeners with Aqua Sensor Sensing Device are tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also comp...

Page 61: ...nd certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness cal cium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also complies with specific performance specifications intended to minimize the amount of regenerant brine and water used in it...

Page 62: ...ted and certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also complies with specific performance specifications intended to minimize the amount of regenerant brine and water used i...

Page 63: ...ertified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness cal cium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also complies with specific performance specifications intended to minimize the amount of regenerant brine and water used in its op...

Page 64: ... and certified by WQA against NSF ANSI Standard 372 CSA B483 1 NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium barium and radium 226 228 as verified and substantiated by test data An efficiency rated water softener is a DIR softener which also complies with specific performance specifications intended to minimize the amount of regenerant brine and water used in i...

Page 65: ...ft Minder Meter N A Manufacturer Culligan International The water treatment device s listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants Barium Radium 226 228 Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organic Contaminants Do not use where water is mic...

Page 66: ...r Soft Minder Meter N A Manufacturer Culligan International The water treatment device s listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants Barium Radium 226 228 Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organic Contaminants Do not use where water is...

Page 67: ...ficate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants Barium Radium 226 228 Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organic Contaminants Do not use where water is microbiologically unsafe or with water of unknown quality except that systems certified for cyst reduction m...

Page 68: ...ficate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants Barium Radium 226 228 Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organic Contaminants Do not use where water is microbiologically unsafe or with water of unknown quality except that systems certified for cyst reduction m...

Page 69: ...nal _____________ gallons Soft Minder Models Total Capacity ______________ gallons Soft Minder Models Number of People in Household______________________________________________________________ Tank Size ______________ inches Water Analysis Total Hardness _____________________________________________________________________ gpg Total Iron ___________________________________________________________...

Page 70: ...66 01023052 Electrical Schematic ...

Page 71: ...E BRINE PISTON DETAIL 7 9 57 25 64 61 60 24 20 18 19 14 15 11 16 12 1 15 11 16 12 14 1 24 20 18 19 17 51 6 51 54 53 55 56 2 2 4 23 28 10 41 41 5 8 29 31 32 28 23 7 6 9 2 63 62 65 42 31 32 28 23 29 2 4 33 17 23 5 8 38 37 47 47 29 40 71 N m 41 42 31 32 28 23 CONTROLLER DETAIL 39 O RING GROOVES PLUG EDUCTOR HOUSING 34 35 1 69 71 69 70 72 83 82 71 72 70 ...

Page 72: ...onnector 10ea Kit 43 01023589 Electronics Enclosure Kit less Circuit Board Control 2 45 P1022796 Eductor Throat with O rings Downflow Tan 10ea Kit Item Part No Description 45 P1022723 Eductor Throat with O rings Downflow Blue 10ea Kit 45 P1023712 Eductor Throat with O rings Upflow Gray 10ea Kit 45 P1023713 Eductor Throat with O rings Upflow White 10ea Kit 46 P1020603 Eductor Throat O ring Large 10...

Page 73: ...UAD RING GROOVE 49 BRINE PISTON DETAIL PISTON DETAIL O RING GROOVES 44 45 QUAD RING GROOVE 48 82 83 71 67 72 70 57 51 55 53 54 56 23 23 22 24 51 50 5 6 28 7 3 2 1 14 14 13 8 9 12 21 10 39 2 7 3 50 22 24 51 5 6 28 4 4 12 8 9 11 13 15 17 14 14 84 34 50 45 46 47 49 48 35 34 O RING GROOVES 53 52 52 53 UPFLOW ONLY 14 10 ...

Page 74: ...nclosure Kit without Circuit Board Twin Control 2 Outdoor includes items 7 9 31 32 33 35 36 43 45 P1022796 Eductor Throat with O rings Downflow Tan 10ea Kit P1022723 Eductor Throat with O rings Downflow Blue 10ea Kit Item Part No Description P1023712 Eductor Throat with O rings Upflow Gray 10ea Kit P1023713 Eductor Throat with O rings Upflow White 10ea Kit 46 P1020603 Eductor Throat O ring Large 1...

Page 75: ... Description 01020553 Remote Display 1 01020749 Remote Display Circuit Board 2 01020750 RF Board 3 01020611 Transformer 4 01020447 Smart Brine Tank Sensor Indoor 4 01025557 Smart Brine Tank Sensor Outdoor 01020747 Modem Parts List Remote Display and Smart Brine Tank Sensor ...

Page 76: ... 10 w Fillport Empty 01016520 Tank Replacement 12 w Fillport Empty 01016522 Tank Replacement 14 w Fillport Empty 01016347 Tank Replacement 9 w o Fillport Empty 01016348 Tank Replacement 10 w o Fillport Empty 2 01009847 Top Strainer Fine Slot 01011195 Top Strainer Wide Slot 1 3 P1009099 O Ring Manifold 1 4 01016176 Outlet Manifold 9 1 4 01014539 Outlet Manifold 10 1 4 01014540 Outlet Manifold 12 1 ...

Page 77: ...18705 Brine System 250 lb 01018715 Brine System 375 lb 1 01018709 Replacement Tank 250 lb 01018716 Replacement Tank 375 lb 2 01018704 Cover 250 lb 01018717 Cover 375 lb 3 01018707 Salt Plate 250 lb 01018713 Salt Plate 375 lb 4 01018707 Brine Chamber 250 lb 375 lb 5 01018706 Brine Valve ...

Page 78: ...Well Cap 24 Pack 3 P1020196 3 8 Compression Nut 24 Pack 4 P1018871 3 8 Insert 25 Pack 5 P1012091 Retaining Clip 24 Pack 6 P1020192 Pin 24 Pack 7 P1020193 5 16 Nut 24 Pack 8 P1020190 Overflow Fitting w Nut 24 Pack 9 P1020195 3 8 Nut 24 Pack 10 P1020198 Air check Assembly 24 Pack 11 P1020197 Float 24 Pack Parts List Brine Valve Assembly ...

Page 79: ...1 3 Item Part No Description 01018720 Brine System 650 lb 1 01018718 Replacement Tank 650 lb 2 01018719 Cover 650 lb 3 01018909 Salt Plate 650 lb 4 01018708 Brine Chamber 5 01018706 Brine Valve Parts List 24 Brine System ...

Page 80: ... product performance specifications are furnished with each water conditioning unit TO THE EXTENT PERMITTED BY LAW CULLIGAN DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITA TION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE TO THE EXTENT REQUIRED BY LAW ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE ONE YEAR PERIOD SPECIFIED ABOVE FOR THE ENTIRE CONDITIONER ...

Page 81: ... Hey Culligan Man Because we re the water experts And that s who you want taking care of your water The Culligan Promise At Culligan we understand that a water quality improvement system is an investment in your family s well being That s why our 1 350 independently operated dealers worldwide don t just sell products they sell water quality you can count on We stand behind our products with writte...

Page 82: ...Softness 8 17 18 19 Dial a Softness Knob 19 Dissolved Iron 5 DOWN ARROW 29 DOWN ARROW button 29 Downflow Regeneration 2 Down Flow Regeneration 8 9 11 Drain Facilities 11 Drain Line Connection 21 Dubl Safe valve 6 E Eductor 15 Eductor Nozzle and Throat Replacement 16 Eductor Nozzle Replacement 15 Eductor Nozzle Throat 15 Electrical Connection 26 Electrical Facilities 11 Electrical Installation 33 E...

Page 83: ... Aqua Sensor Start Up Procedure 41 Recommended Meter Start Up Procedure 40 Recommended Preventative Maintenance Inspection Schedule 43 Regeneration 6 8 38 Regeneration Setup 33 Remote Display and Smart Brine Tank Sensor 71 Replace Aux Filter Media 47 Replace Ext Filt 47 S Salt Bridging 47 Salt Delivery Service 42 Salt Economizer 42 Salt Storage Container 22 Salt Storage Tank 9 Salt Storage Tank As...

Page 84: ......

Reviews: