Installation
9
Placement
Refer to Figure 9 for system placement.
•
Set the media tank on a solid, level surface near water, drain and electrical facilities. Place the
outlet (black coupling) of the tank on the left.
•
Set the brine system on a flat, smooth, solid surface as near the media tank as possible.
Mount The Control Valve - 3/4” Control
See figure 10 for a visual on mounting the control valve to the tank.
As shipped from the factory the Culligan Medallist Series
®
3/4” control is equipped as a 8” unit.
1. Remove the two plastic caps from the tank couplings and lubricate the coupling O-rings with
silicone lubricant.
2. The control valve is marked also with “IN” and “OUT”. Place the control onto the tank with the
inlet and outlet of the control corresponding with the inlet and outlet of the tank. Press firmly onto
the couplings.
Figure 9
Note: Do not use a petroleum base lubricant, for this will cause swelling of the rubber parts.
Note: The black molded tank adapter is marked with “IN” and “OUT”, corresponding to
the inlet and outlet of the tank. Position the tank with the inlet coupling on the right and the
outlet coupling on the left as you face the front of the tank.