Flow 24” Orifice Stir Fan
DIMENSIONS
30.25
”
Vertical
30.25
” Horizontal
24 inch Stir Fan
Installation
A. Orifice fans are intended to be securely mounted by
hanging from a chain or cable but may be installed in a
wall.
B. DO NOT install fan within 7 feet of floor or in reach of
personnel or livestock.
C. FAILURE TO GUARD MOVING PARTS MAY RESULT IN
SERIOUS INJURY OR DEATH.
D. Disconnect AC electrical power from all equipment.
E. Make wire connections to the fan as shown on the fan
motor wiring label and in the controller manual.
F.
Mount the 24” stir fans as shown in the diagram in
Figure
3.
G. Ensure that all wires near the fan are secured and safely
clear from the fan blades.
H. Apply power and test the controller and fans to ensure
proper operation.
IMPORTANT! INSPECT FAN FOR ANY OBJECT THAT
MAY OBSTRUCT BLADE ROTATION.
Figure 3
Fan Mounting Diagram
WARNING!
WIRING MUST BE
SECURED TO PREVENT
ENTANGLEMENT WITH
THE FAN BLADES.
Remove ALL Electrical
Power before
installation/wiring.
WARNING!
Secure fan ONLY to a
ceiling with strength to
support the fan weight and
vibrations.
IMPORTANT:
Tilt the fan upward 2 inches from the
vertical plane in the direction shown.
WARNING!
Remove ALL Electrical Power from the system before
installation / wiring.