2. Smart-Flex (FLX-4629) Operation Instructions
10
PNEG-1186
Smart-Flex (FLX-4629) Operation Instructions
Setting the Unit I.D. Number (Only Used with Network Master)
When configuring the Smart-Flex to be used with a Network Master, each Smart-Flex must have a unique
unit I.D. number in order to communicate properly. There is a maximum of twenty five (25) Smart-Flex
controls that can be used with each Network Master. The unit I.D. number of each Smart-Flex must fall
between a range of “0051” and “0075”. “0000” is the default setting and indicates no unit I.D. number.
Be sure to record this I.D. number along with a brief description of its location, for each Smart-Flex, for use
when programming the Network Master.
To Set the Unit I.D. Number
1. Push both arrow up and arrow down buttons at the same time, then release. Initially the default
setting of “0000” indicating no unit I.D. number, will be displayed.
2. Use the arrow button up or down to scroll through to the desired unit I.D. number from “0051”
through “0075”.
3. Once the unit I.D. number is selected, push the
Set/Clr
button to save this setting.
4. Record this unit I.D. number along with a brief description of its location for future use when
programming the Network Master.
5. If a unit I.D. number is set on the Smart-Flex un-intentionally, after 15 minutes, an alarm code of
“AC14” will be displayed, indicating a communication error. Press the
Set/Clr
button to clear this
alarm code. To disable the unit I.D. number, set to “0000”.