Transport
Fig.1.
Fitted with personal protection equipment, trans-
port the appliance to the installation location. Use a suitable vehi-
cle capable of withstanding the weight of the same.
Model
single
double
Model
single
double
DN435
147 kg - 324 lb
252 kg - 555,5 lb
DN635L
190 kg - 418,8 lb 324 kg - 714,2 lb
DN635
187 kg - 412,2 lb 330 kg - 727,5 lb
DN935
250 kg - 551,1 lb 430 kg - 948 lb
Persons not involved with the appliance installation may not
pass through or stand in the work area during the transport of
the appliance. During the transport, pay particular attention to
passing through openings and/or doors.
Preliminary operations
Fig.2.
Carefully remove the protective film.
If any glue residue is left on the surfaces, remove it with soapy
water but without any corrosive or abrasive products or sharp or
pointed instruments.
Check that all the parts making up the oven are in good con-
dition and without any faults or breakages, if that is not the
case, contact the Retailer for the procedures to follow.
Positioning
The positioning room must comply with the instructions provid-
ed in
Fig.3.
Fig.4.
The oven must be placed on a base, built by the Manu-
facturer or by yourself that:
• is flame and heat resistant;
• is perfectly stable and level;
• withstands the weight of the appliance.
In both cases, silicone the gap between the oven and the sup-
port or the bearing surface, using high temperature resistant sili-
cone (for USA versions only).
Comply with the measurements shown in the figure
Fig.5.
Serial number plate reading
Fig.6.
The serial number is on the right hand side of the ap-
pliance. It provides important technical information that is vital
in case of a request for maintenance or repair of the appliance:
please do not remove, damage or modify it.
Smoke extraction
The oven is fitted with a flue in the top to get rid of the steam
from the cooking chamber.
This steam, together with the one from the door during the work
phases,
must be conveyed outside
in one of the following
ways:
Fig.7.
A
through a
hood supplied by the Manufacturer
that ensures
perfect compatibility with the oven. For correct assembly and
fixing to the oven, see the sheet attached to it; the evacuation
flue must be for the exclusive use of the appliance, comply
with current regulations and have a diameter that allows the
passage of a
ø150 mm
[Ø 5.91 in.]
evacuation pipe which
corresponds to the diameter of the tube to be fitted on the
hood (not supplied).
B
through a
hood
belonging to the user, of suitable capacity,
placed at about
300 mm
[Ø 11.81 in.]
from the oven;
C
through an adequate
extraction system
supplied by
the user connected to the oven flue: in this case a draught
switch must be installed between the extractor and the oven
chimney (the extractor, switch and tube are not supplied
by the Manufacturer). In this type of installation, the fumes
resulting from the opening of the door will not be extracted.
Electrical connection
The electrical connection must be carried out
exclusively
by qualified personnel after reading the safety warnings
at the beginning of the manual.
Before installing the appliance,
check that systems
comply with the regulations in force
in the country
where it is going to be used and
with the specifications
indicated on the appliance rating plate
on the RH
side of the oven.
Fig.9.
The appliance is supplied without either power cable or
plug: they must both be fitted by qualified personnel. The cable
must be only
of the type stated
and the plug fitted to it must
be suitable for the consumption and connection of the oven to
the electrical mains.
If the oven is fitted with a double chamber, there are two
power cables and two plugs.
To connect the cable to the appliance, remove the RH side panel
of the oven, let the cable through the cable gland provided and
connect it to the terminal block correctly.
For a correct electrical connection, the appliance must:
•
Fig.8.
be included in an
equipotential system
in
compliance with the legislation in force. This connection
must be made between the various devices with the terminal
marked with the equipotential symbol
. The cable must
have a maximum cross-section of 10 mm2 (in compliance with
IEC EN 60335-2-42:2003-09) and must be yellow-green;
• must be
grounded
to the mains (green-yellow wire);
• must be connected to a
thermal differential switch
in com-
pliance with the regulations in force (0.03A A type);
• must be connected to an
omnipolar circuit breaker
allowing
complete disconnection in overvoltage III category conditions.
The Manufacturer accepts no liability for failure to comply with
the above.
If required, the cable can be replaced by the Dealer or its
technical service or by a person with similar qualifications
to prevent any risk.