background image

OPERATING INSTRUCTIONS — 453 PVC Heater

1. Place PVC conduit heater on a flat, dry surface. Plug heater into a grounded

power source. Turn switch to ON position. Rollers will begin to rotate.

2. Put on insulated gloves.

3. After warm-up period, ( approximately 7 min. ) place conduit on rollers

inside the heater. Using the handle, close the door(s) over the section 
of PVC to be heated.

4. To test, lift one end of the PVC conduit. Conduit is ready when it has 

a glossy appearance and bends when lifted.

NOTE: PVC conduit MUST be rotated to provide even heating and 
to prevent scorching.

NOTE: PVC conduit will take approximately 30 seconds to heat for 
each 1/2” of PVC conduit diameter. ( Example: 2” PVC conduit will 
heat in approximately 2 minutes.)

5. Open the heater door(s) using the handle and remove conduit from heater 

and place on a clean, flat surface. Hand bend to desired angle. The bend 
can be set by allowing to air cool or decrease this time by rubbing the

bend with a sponge soaked in cool water. NOTE: Be Sure to keep all 

liquids away from the PVC heater and turn unit off when not in use.

PVC CONDUIT HEATER ACCESSORIES

• To prevent flattening and crimping during the bending process, Current Tools 

plug sets are recommended for 2” and larger PVC conduit.

• Current Tools Model #454 PVC support stand is recommended to prevent 

sagging of the conduit during the heating process.

3

WIRING SCHEMATIC

HEATER

POWER ON/OFF

230V AC
28 AMP

WHITE

BLACK

GREEN

BLACK

WHITE

M

RESISTOR

ELEMENT

6400 
WATT

INDICATOR 
LAMP

BLACK

BLACK

WHITE

WHITE

Summary of Contents for 453

Page 1: ...s manual and read and understand its contents To request a copy call or write to the address below All information specifications and product designs may change due to design improvements or updates and are subject to change without notice Current Tools does not assume any liability for damages resulting from misuse or incorrect application of its products CURRENT TOOLS P O BOX 17026 GREENVILLE SC...

Page 2: ... handle to open and close the PVC heater door s DO NOT use in wet conditions DO NOT expose to rain or moisture DO NOT use near flammable materials DO NOT leave PVC heater unattended Turn PVC heater off when not in use Use for heating PVC conduit only DO NOT use for any other purpose Use only for PVC conduit sizes specified Operate only in a well ventilated area Use only with a grounded power sourc...

Page 3: ...uit diameter Example 2 PVC conduit will heat in approximately 2 minutes 5 Open the heater door s using the handle and remove conduit from heater and place on a clean flat surface Hand bend to desired angle The bend can be set by allowing to air cool or decrease this time by rubbing the bend with a sponge soaked in cool water NOTE Be Sure to keep all liquids away from the PVC heater and turn unit o...

Page 4: ...7 33 28 41 34 49 20 19 50 51 42 11 8 2 12 38 37 10 23 24 54 44 40 43 38 45 48 31 32 37 47 35 36 9 46 47 26 17 23 3 39 22 25 29 53 6 47 13 23 26 29 5 4 24 25 12 2 1 16 23 22 14 21 52 EXPLODED VIEW 453 PVC HEATER 4 4 ...

Page 5: ...4K 5 10 32 HEX NUT 26 451 21 3 SLOTTED MACH SCREW 10 32 X 5 8 27 453 16B 2 8 FLAT WASHER 28 453 16A 2 8 32 HEX NUT 29 453 24 3 10 LOCK WASHER 30 453 10A 2 RETAINING RING EXTERNAL 5 16 31 450 11A 2 SOC HD CAP SCREW M8 X 12 32 450 11B 2 M8 LOCK WASHER 33 451 25 2 1 2 FLAT WASHER 34 451 23 2 COTTER PIN 3 32 X 3 4 35 452 27 2 3 8 LOCK WASHER 36 452 28 2 3 8 16 HEX NUT 37 453 19 9 SET SCREW 1 4 20 X 1 ...

Reviews: