background image

Emergency LED Battery Pack Installation, 

Operation, and Service Instructions

CLASS 2 OUTPUT

P/N:93071774

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should 

always be followed including the following.

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

 

Do not join converter connection until installation is complete and AC power is supplied to the emergency driver.

1.  This product is for use with an emergency LED lighting load and supplies 10.0 W of constant output power to 

LED lamps rated from 20-56 Vdc. Operates emergency LED load in the emergency mode for a minimum  

of 90 minutes.

2.  Make sure all connections are in accordance with the NEC and any local regulations.

3.  To reduce the risk of electric shock, disconnect both normal and emergency power supplies and converter 

connector from the emergency driver before servicing.

4.  This emergency driver is suitable for factory or field installation inside of a suitable lighting fixture. 

5.  Do not use outdoors. This product is suitable for use in damp locations where the ambient temperature is 0°C 

minimum, +55°C maximum. Product is not suitable for heated air outlets and wet or hazardous locations.

6.  An unswitched AC power source is required (120-277 VAC, 50/60 Hz).

7.  Do not install near gas or electric heaters.

8.  Do not attempt to service the battery. A sealed, no-maintenance battery is used that is not field replaceable. 

Contact Dual-Lite for information on service.

9.  The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

10.  Do not use this product for other than intended use.

11.  Servicing should be performed by a qualified service personnel.

12. Equipment should be mounted in locations and at heights where it will not be subjected to tampering by 

unauthorized personnel

 

SAVE THESE INSTRUCTIONS

WARNING

 - 

This product contains chemicals known to the State of California to cause cancer, birth 

defects, and/or other reproductive harm. Thoroughly wash hands after installing, cleaning, 

or otherwise touching this product. 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 

to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 

interference when the equipment is operated in a commercial environment. This equipment generates, 

uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 

instruction manual, may cause harmful interference to radio communications. Operation of this equipment 

in a residential area is likely to cause harmful interference in which case the user will be required to 

correct the interference at his own expense.

CAUTION: DISCONNECT POWER DURING INSTALLATION AND BEFORE SERVICING. 

READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.

PLD10

ALB

ALB

EC-160127003

5/11/16

1

4

3

D

C

B

A

4

3

2

1

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

SHT 1

1 SHTS

---

---

93071774

93071774

1

ILL-EV10 BATT PACK

ALB

05/11/16

ALB

5/11/16

---

ALB

5/11/16

NTS

REV.

DRAWING NO.

SIZE

SCALE

PART NO.

FINISH:

MATERIAL:

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

DIMENSIONS IN INCHES
DIMENSIONS IN [ ] IN MM
CONFORMS TO ASME Y14.5M
DO NOT SCALE PRINT

DRAWN BY:

THIRD ANGLE PROJECTION

CHECKED BY:

ENGINEERING:

CATALOG NO.

CRITICAL DIMENSIONS

C

UNSPECIFIED TOLERANCES: INCHES

X.XX=

u

0.12 

FRACTIONS=

u

1/32 ANGULAR TOLERANCE=

u

1

v

THIS ILL IS ON INSTRUCTION SHEET 93070924.

SEE UNIT LABEL FOR ADDITIONAL MODEL SPECIFICATIONS

SAVE THESE INSTRUCTIONS FOR USE BY OWNER/OCCUPANT

INSTALLER:

Summary of Contents for Dual-Lite PLD10

Page 1: ...NSTRUCTIONS WARNING This product contains chemicals known to the State of California to cause cancer birth defects and or other reproductive harm Thoroughly wash hands after installing cleaning or otherwise touching this product This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide r...

Page 2: ...ield installation with suitable LED loads including LED luminaires DC voltage driven LED replacements for fluorescent lamps and others There are 4 checks to determine if you luminaire is eligible for field installation NOTE This product has been designed to reliably interface with a wide selection of LED loads and is electrically compatible with every simple LED array that meets criteria 1 4 above...

Page 3: ...in the converter battery connector Step 8 At this point power should be connected to both the AC driver and the emergency driver and the charging indicator light should illuminate indicating the battery is charging Step 9 A short term discharge test may be conducted after the emergency ballast has been charging for one hour Step 10 Charge for 24 hours before conducting a long term discharge test R...

Page 4: ...The LED load should operate at reduced illumination 3 Conduct a 90 minute discharge test once a year by turning off the AC circuit breaker at the service panel The LED load should operate at reduced illumination for at least 90 minutes REFER ANY SERVICING INDICATED BY THESE CHECKS TO QUALIFIED PERSONNEL Recycling Information NOTE For short term testing of the emergency function the battery must be...

Reviews: