Battery Reverse Polarity
Full protection against battery reverse polarity, no damage to the controller will result. An error
code b02 will display on the LCD screen. This code indicates the positive and negative
connections to your battery are the wrong way around. Disconnect the wires from the battery and
reconnect making sure the positive lead is connected to the positive terminal on the battery and
the negative lead is connected to the negative on the battery.
It is recommended to move the solar kit indoors during rain, hail or storms.
Specifications
Type
Folded
Size
Weight
Max
Power
Max
Power
Voltage
Max
Power
Current
Open
Circuit
Voltage
Model
mm
kg
W
V
A
V
CT-K140
525x505x75
11
140
18.8
7.44
22
Solar Cell: Monocrystalline
WARNING
DO NOT CHARGE A BATTERY DIRECT FROM THE SOLAR
PANELS WITHOUT CONNECTING TO THE SOLAR
CONTROLLER PROVIDED OR AN EXTERNAL SOLAR
CONTROLLER.
A REGULATOR MUST BE USED TO CHARGE ALL
BATTERIES.
CHARGING DIRECT FROM THE SOLAR PANEL WITHOUT
CONNECTING A SOLAR CONTROLLER COULD CAUSE
INJURY, DAMAGE TO YOUR BATTERIES OR CAUSE A
BATTERY TO EXPLODE.