FILTER - SILENCER
(Rotary Blower)
A)
General : The air blower filter - silencer is mounted on the air blower. Dirt and
other foreign particles are filtered from the incoming air by means of
the reusable stainless element. The design is such that it partially
silences the air also.
Note :
Do Not run the machine without this filter silencer assembly; as this would cause
serious damage to the blower unit.
BLOWER FILTER ASSEMBLY
B)
Removal and disassembly :
1.
Remove the filter-silencer from the air blower by turning it counter-clockwise.
2.
Remove wing nut and washer.
3.
Remove outer shell cover.
4.
Remove stainless element.
C)
Inspection and Cleaning :
1.
Clean the stainless screen in an approved solvent, dry with compressed air, or
shake to remove excess solvent and allow to dry naturally. Inspect the screen for
defects that may permit dirt or other foreign particles to enter the air blower.
2.
Inspect the outer shell cover for cracks, breaks or dents and replace if required.
3.
Remove any foreign matter of obstruction from any of the tubes of the main base
assembly. Be careful not to loose the clips from the base which isolate the shell
from the base to prevent excessive vibration.
23
WING NUT
WASHER
COVER
STAINLESS
STEEL
ELEMENT
BASE
ASSEMBLY