Hurricane ES Owner’s Manual
9
formulation can ignite if the proper conditions exist. These conditions are basically two: 1) a
sufficient volume of liquid in the form of fine particles suspended in the air; and
2) A sufficiently high energy source of ignition
2.1
Safety Precautions (continued)
3. Aerosol Concentration
. It has been fully established that an acceptable level of liquid in
the atmosphere is one gallon per 50,000 cubic feet (2.7 liters per 1,000 cubic meters). There is
a safety margin of at least 5 to 1 in this figure.
4. Aerosol Ignition
. If a combustible atmosphere is established or a combustible deposit is
laid down, a source of ignition may cause a fire. Sources of ignition can be gas or oil pilot
lights or sparks from electrical controls. Therefore, it is strongly recommended that all such
sources be eliminated by extinguishing all pilot lights and turning off all unnecessary electric
power. To avoid danger of fire or explosion in an enclosed space, the enclosed volume
fogging time and required formulation volume should be carefully calculated.
While operating
the machine, always carry the machine by the carrying handle to ensure that you are properly
grounded.
5. Proper and Improper Use.
The following rules apply to the operation of this machine:
2.2
Read the entire manual before operating the machine and pay particular attention to all
CAUTIONS AND WARNINGS.
▪
Only use water-base formulations with this machine
▪
Store formulation in its original labeled container.
▪
Only use a 3-prong grounded extension cord which is properly rated for voltage,
current, and length and which is free from nicks, cracks, and other signs of prior abuse.
For lengths up to 100 feet, (30.5 meters) cords with No. 12 AWG wire are usually
adequate.
▪
Turn off sprayer before unplugging. Unplug by grasping the plug. Do not pull on cord to
unplug. Do not unplug machine with wet hands.
▪
Replace damaged or worn electric cord immediately.
▪
Turn the flow valve CLOCKWISE to the OFF position after each spray application while
the motor is still operating to allow clearing of the lines. This will also prevent a possible
siphon effect if the unit is ever accidentally knocked over with the valve remaining open.
▪
Always comply with any requirements for protective clothing, goggles, gloves, facial
masks, or respirator required by the formulation label.
DO