29
FORMULATION FILTER
The system is equipped with an in line low profile filter located at the formulation tank
standpipe. This filter is to prevent any foreign matter from entering the 3-way solenoid
valve and the nozzle system. Located inside the filter housing is a fine mesh stainless
steel screen and an Atlas gasket seal.
IN-LINE FILTER (P/N 62558-5)
TO REMOVE AND CLEAN THE SCREEN
1
.
Loosen and remove the bottom portion (bowl) from the housing body, being
careful not to loose the A
t
las gasket seal ring.
2. Remove and clean the fine wire mesh stainless steel screen.
3. Check the Atlas gasket seal ring and replace if necessary.
CAUTION
Do Not over tighten as damage to the Aflas gasket seal ring may occur.
Over
tightening will not improve the seal.
Note:
If leakage occurs, open the unit and clean and inspect the Atlas gasket seal ring.
A suitable lubricant applied to the ring will help the seal.
62558-4
62558-1
10200-124
62558-3