4
conditions, the three Pulse Brew options help “tune” or change the coffee flavor. Filter Pack type coffees typically extract
better with the A and B pulse setting. Decaf coffees typically extract better with the B pulse setting. High-Yield coffees
typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to suit your taste
profile. Settings D and E are manual pulse counts. If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1
within 5ºF of set point and Cold Brew Lock disappears from the list of program selections.
When Pulse Brew is ON, Pre-infusion disappears from the list of program selections.
Drip-out Mode
(Factory set to 2 minutes)
Press
to Select. Press < or > to move to desired time. Settings are OFF, 1, 2, 3, 4 and 5 minutes. Press
to Select
time.
Temperature
(Factory set to 204°F)
Press
to Select. Press < or > to move to desired temperature and then
to set. Temperature is programmable from
170ºF to 204ºF in 2-degree increments.
Energy Save Mode
(Factory set to OFF)
Press
to Select, < or > ON, OFF or ON 140ºF ,
to set. When in ON, unit will automatically shut off 4 hours from
last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF, if unit has not brewed in 4 hours. This feature will save
energy by maintaining a lower temperature in the tank in periods of non-operation.
Brew Count Odom
Press
to display total brew cycles. Press ex or Reset
Brew Count Total
Press
to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Cold Brew Lock
. . . (Factory set to 5º )
Press
to select, < or > to select desired setting (CBL 5, 15 or OFF),
to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.
The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set
point for the Ready to Brew message, however, it will brew at any temperature.
Master Reset
Press
to display Are You Sure?
Then < for Yes, > for No. Brewer factory defaults are then reset.
Service Call
(Phone number Factory set to 1-800-000-0000)
Press
to display number and change number or < to move place and EX to exit when complete. This number will be
displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code
(Factory set to 1-2-3-4)
Press
to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit
when complete.
Banner Name
(Factory set to CURTIS)
Press
to display letters and change letters or < to move place and EX to exit when complete
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks
disables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.
P-Maintenance
(Factory set to OFF)
Press
to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.
Press
to exit.
Beeper On/Off
(Factory set to ON)
Press
to display ON or OFF. Pressing either < or > toggles between on and off.
to set. When ON, this feature al-
lows you to hear a short beep each time a button is pressed.
Energy Save Mode
Coffee
Drip-out Mode
Temperature
Beeper On/Off
P-Maintenance
Banner Name
Access Code
Service Call
Master Reset
Cold Brew Lock
Brew Count Odom
Brew Count Total
Continued on Page 5