5
Half Batch
(Factory set to OFF)
Activates Half Brew buttons. Press
to display ON or OFF. Pressing either < or > toggles between on and off. When
this feature is ON, a half batch button can be used on the control panel.
Displ. Brew Time
(Factory set to ON)
Press
to display ON or OFF. Pressing either < or > toggles between on and off.
Safety Sw On/Off
(Factory set to ON)
Press
to display ON or OFF. Pressing either < or > toggles between on and off.
to set. When this feature is turned
OFF, the tea brewing safety switch is by-passed. You may brew tea without having to depress the switch.
Exit
Press
to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.
Exit
Displ. Brew Time
Half Batch
Safety SW On/Off
Program Menus
Error Message
With G3/Golden Cup Series brewers, there are three error messages that can appear on the screen to advise the user of a malfunction. If one of
these error messages appear, the brewer will lock up and stop functioning until the error is corrected. An error message will occur under the follow-
ing conditions:
1. Water level fill error or overflow. This error message occurs when the inlet valve solenoid has been on for more than 10
minutes. This error message also occurs when the valve is refilling the tank during a brew cycle for more than 1½ minutes.
2. Water temperature control system error. An open probe or a break in the temperature control circuit is detected.
3. This error message indicates that the safety switch (centered on the front panel) was not pressed when the user was at-
tempting to brew tea. The tea brewing container must be pushed back against the switch to allow brewing to continue.
The screen may display a phone number to call for service. After the malfunction is corrected, the error message must be
cleared. To reset the control panel and return to normal operation, press
for 5 seconds.
Place Container
Against Switch
(800) 000-000
Sensor Err
(800) 000-000
Water Level Err
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water Temperature will be
displayed (temperature in heating tank).
Tea Tips
1. Store tea bags in a dark, cool and dry place away from strong odors and moisture. Do not refrigerate.
2. Never hold finished brewed tea for more than eight hours at room temperature. Discard any unused tea after eight hours
3. Brew only enough tea that you reasonably expect to sell within a few hours.
4. To protect tea flavor and to avoid bacterial contamination and growth, clean and sanitize tea brewing, storage and dispensing equipment at
least once a day.
WARNING
DO NOT refrigerate unused tea overnight for later consumption.
Summary of Contents for CBP
Page 10: ...Electrical Schematic ...
Page 11: ...Rough In Drawing ...