CLEANING INSTRUCTIONS - CBFX
CI34
CFBX, CLEANING INSTRUCTIONS
082619J
Daily Cleaning (cont.)
Remove the Mixing Bowls and Lids
8 Remove the tap lever assemblies from
the bowl taps by pushing in on the top
of the tap lever with your thumb while
pulling up on the bottom with your
JOEFYmOHFS
9 Lift off the bowl lids.
10 Remove the bowl by pushing the front
up and pulling outward on the trim on
the bottom.
11 Pull the bowl seal off of the back of
each bowl.
NOTE:
Sometimes the seal
comes loose and sticks to the auger
when the bowl is removed.
12 Pull forward on each auger to remove
it from the drum.
13 *If the unit was used to freeze dairy
products, remove the auger seal from
each drum.
14 Inspect all auger, bowl and tap seals.
Replace all worn seals with new ones.
Replace the auger seals every 6
months, regardless of condition.
Clean and
Sanitize
the Mixing Bowl Parts
15 Fill a container with a sanitizing
solution mixed in water (2% of sodium
hypoclorite mixed in water). Soak
the tap parts, auger and seals in the
sanitizing solution. Scrub with a soft
cloth. Allow 30 minutes for the solution
to act. Rinse thoroughly with clean
water, then air dry.
16 Using a sponge dipped in sanitizing
solution, clean the lids, bowls and
drums. Clean the underside of the
lid using a brush soaked in sanitizing
solution. Allow 30 minutes for the
solution to act. Rinse thoroughly with
clean water, then air dry.
continued...
NOTICE:
Failure to replace
worn seals may result in leaks.
8
10
12
15
13
16
9
11
Auger
seal*
Auger
Sanitizing
30
solution
Soak sponge and brush
in sanitizing solution
Bowl
seal
c
c
d
d
Pull outward
here