background image

WARRANTY

FOR THE LATEST SPECIFICATION INFORMATION GO TO WWW.WILBURCURTIS.COM

Printed in U.S.A.     8/20/03       F - 1904 rev A

WILBUR CURTIS CO., INC.

6913 Acco St., Montebello, CA 90640-5403 USA
Phone: 800/421-6150  

   

Fax: 323-837-2410

 

 Technical Support Phone: 800/995-0417 (M-F 5:30A - 4:00P PST)      E-Mail: techsupport@wilburcurtis.com

 

 Web Site: www.wilburcurtis.com

We hereby certify that the products manufactured by the Wilbur Curtis Company, Inc., are, to thebest of our knowledge,
free from all defects and faulty workmanship.
The following warranties and conditions are applicable:

1.

1 Year Parts & Labor from Date of Purchase from Factory: 

This warranty covers all electrical parts, fittings

and tubing.

2.

 40 Months or 40, 000 Pounds of Coffee on a set of Grinding Burrs. (ADS Grinders)

3. 

 3 Years from Date of Purchase: 

This warranty covers electronic control boards and leaking or pitting of a

stainless steel body of a Brewer or Urn.

4.

90 Days from Date of Purchase: 

On replacement parts that have been installed on out of warranty equipment

All in-warranty service calls must have prior authorization from the manufacturer. For an RMA (Return Merchandise
Authorization) number, call the Technical Service Department at 1-800-995-0417. The Wilbur Curtis Company will allow
up to 100 miles, round trip, per in-warranty service call.

CONDITIONS & EXCEPTIONS

The warranty covers original equipment at time of purchase only. The Wilbur Curtis Company, Inc., assumes no
responsibility for substitute replacement parts installed on Curtis equipment that have not been purchased from the
Wilbur Curtis Company. Inc The Wilbur Curtis Company will not accept any responsibility if the following conditions are not
met. The warranty does not cover and is void under these circumstances:

1) Improper operation of equipment. The equipment must be used for its designed and intended

purpose and function.

2) Improper installation of equipment. This equipment must be installed by a professional,

certified technician and must comply with all local electrical, mechanical and plumbing codes.

3) Wilbur Curtis Company will not be responsible for the operation of equipment at other than the

stated voltages on the serial plate.

4) Abuse or neglect (including failure to periodically clean or remove lime accumulations).

Manufacturer is not responsible for variation in equipment operation due to excessive lime or
local water conditions.

5) Replacement of items subject to normal use and wear. This shall include, but is not limited to,

light bulbs, shear disks, “0” rings, gaskets, canister assemblies. whipper chambers and plates,
mixing bowls, agitation assemblies and whipper propellers.

6) Any faults resulting from inadequate water supply. This includes, but is not limited to, exces-

sive or low water pressure, and inadequate or fluctuating water flow rate.

7) All repairs and/or replacements are subject to our decision that the workmanship or parts were

faulty and the defects showed up under normal use.

8) All labor shall be performed during regular working hours. Overtime charges are the responsibil-

ity of the owner.

9) Charges incurred by delays, waiting time, or operating restrictions that hinder the service

technician’s ability to perform service is the responsibility of the owner of the equipment.
This includes institutional and correctional facilities.

10) All claims under this warranty must be submitted to the Wilbur Curtis Company Technical

Service Department before return of the unit to the factory.

11) All equipment returned to us must be repackaged properly in the original carton. No units will

be accepted if they are damaged in transit due to improper packaging.

12) Damaged in transit.
13) The resetting of safety thermostats and circuit breakers, programming and temperature

adjustments are the responsibility of the equipment owner.

NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION (RMA).
RMA NUMBER MUST BE MARKED ON THE CARTON OR SHIPPING LABEL.

All in-warranty service calls must be performed by an authorized service center, where service is available. Call the factory
for location near you.

8/22/03 . ecn6023 . revA

X

Summary of Contents for GEM 120P

Page 1: ...ouble Shooting Wiring Diagram Illustrated Parts List Warranty 9 7 99 9 8 F 1904 p65 p1X FIND OUT MORE ON THE WEB WILBURCURTIS COM W W W W WILBUR ILBUR ILBUR ILBUR ILBUR C C C C CURTIS URTIS URTIS URTIS URTIS C C C C COMP OMP OMP OMP OMPANY ANY ANY ANY ANY I I I I INC NC NC NC NC WILBURCURTISCOMPANY Montebello CA90640 ISO 9001 REGISTERED C FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO WWW WIL...

Page 2: ...0 Hz Height 28 inches Width 9 inches Depth 16 inches ShippingWeight Approximately47lbs S P E C I F I C A T I O N S GEMINI Curtis Curtis Curtis Curtis Curtis 123 123 24 16 9 4 26 6 ELECTRICAL CORD 1234567890123456 1234567890123456 1234567890123456 12345678 12345678 12345678 ROUGH IN DRAWING GEMINI 120P ...

Page 3: ... preheat the satellite Make sure satellite is warmed up for at least 10 minutes prior to brewing Failure to preheat the insulated satellite will result in an instant drop in coffee temperature 6 The brew light item 6 will come on about 15 to 20 minutes after plugging in the power cord This indicates that the water in the heating tank is at brewing temperature 200º F BREWING COFFEE 1 Place a paper ...

Page 4: ...dup The frequency will depend on local water conditions CLEANING THE SATELLITE SERVER 1 Clean the interior of the Satellite and lid daily after the last batch of coffee is used Use a good nontoxic cleaner You can also clean inside the satellite with a Scotch Briteä pad Rinse thoroughly and dry 2 Outside of the Satellite should be cleaned with stainless steel polish only to prevent surface scratche...

Page 5: ...This will indicate how much current if any is flowing through the wire If no continuity or low amp reading is indicated under 15 amps replace the heating element T T T T TroubleShooting roubleShooting roubleShooting roubleShooting roubleShooting PROBLEM Poor spray pattern over coffee grounds Coffee is not evenly saturated SOLUTION 1 Check all the silicone water tubing for lime buildup and clean ou...

Page 6: ...4 WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM ...

Page 7: ...RA ILLUSTRA ILLUSTRA ILLUSTRA ILLUSTRATED P TED P TED P TED P TED PAR AR AR AR ARTS BREAKDOWN TS BREAKDOWN TS BREAKDOWN TS BREAKDOWN TS BREAKDOWN GEMINI 120P GEMINI 120P GEMINI 120P GEMINI 120P GEMINI 120P 5 ...

Page 8: ...WITCH ROCKER 120V RED LIGHT BREW 115V POUR PAN GEMINI 120P NUT 3 8 JAM NPT NICKEL PLATED O RING I D TUBE I D x 130W SILICONE FITTING POUR PAN GEM 120P FITTING SPRAYHEAD ASSY BRACKET UPPER TANK SUPPORT TUBE 5 16 I D SILICONE GEN USE BUSHING 5 8 SNAP IN NUT 5 8 LOCK BRASS SPRAYHEAD BLUE 178 DIA COVER FRONT DECK WARMER ELEMENT LABEL CAREFUL HOT SURFACE KIT WARMER ELEMENT 100W 120V STRAP WARMER ELEMEN...

Page 9: ...8 8 8 8 11 11 11 11 11 13 13 13 13 13 12 12 12 12 12 10 10 10 10 10 9 9 9 9 9 14 14 14 14 14 17 17 17 17 17 1 1 1 1 1 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 2 2 2 2 2 15 15 15 15 15 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION PART PART PART PART PART N N N N Nº º º º º INDEX INDEX INDEX INDEX INDEX N N N N Nº º º º º GEM 5 WC 1201 WC 114R GEM3 WC 3307 WC 5622 W...

Page 10: ...5D WC 39223 WC 567 WC 37102 1 2 3 4 5 SATELLITE WARMER STAND DIGITAL SHORT 120V SATELLITE WARMER STAND DIGITAL TALL 120V MEMBRANE CONTROL PANEL GEM 5D 8D CONTROL BOARD GEM 5D 8D KIT HEATER ELEMENT 100W 120V 5 5 5 5 5 3 3 3 3 3 3 3 3 3 3 1 1 1 1 1 2 2 2 2 2 4 4 4 4 4 BLACK GRN POWER CORD WHITE 3A 5B 4B WARMER SWITCH WHITE RED WARMER ELEMENT ...

Page 11: ..._____________________________________________________________ ___________________________________________________________________________ ____________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ _________________________________...

Page 12: ...fied technician and must comply with all local electrical mechanical and plumbing codes 3 Wilbur Curtis Company will not be responsible for the operation of equipment at other than the stated voltages on the serial plate 4 Abuse or neglect including failure to periodically clean or remove lime accumulations Manufacturer is not responsible for variation in equipment operation due to excessive lime ...

Reviews: