WARNING:
Electric Shock Hazard -
UIFGPMMPXJOHQSPDFEVSFTBSFUPCFQFSGPSNFEPOMZCZBRVBMJmFETFSWJDFUFDIOJDJBO
%JTDPOOFDU QPXFS XIFO SFQMBDJOH DPNQPOFOUT -PDL PVU BOE UBH UIF DJSDVJU CSFBLFS PO VOJUT XJUIPVU B
QPXFSQMVH/FJUIFS8JMCVS$VSUJT$P*ODOPSUIFTFMMFSDBOCFIFMESFTQPOTJCMFGPSUIFJOUFSQSFUBUJPOPGUIJT
JOGPSNBUJPOPSBOZMJBCJMJUZJODPOOFDUJPOXJUIJUTVTF
Scald and Burn Hazard -
LFFQCPEZQBSUTDMFBSPGIPUTVSGBDFTEVSJOHUSPVCMFTIPPUJOH
Troubleshooting Guidelines
•
*GBOFSSPSNFTTBHFBQQFBSTPOUIFEJTQMBZDPOTVMUUIF
ERROR CODES
TFDUJPOCFGPSFUSPVCMFTIPPUJOH
•
"CSFXFSUIBUJTOPUMFWFMNBZOPUGVODUJPOQSPQFSMZ.BLFTVSFUIFCSFXFSJTQSPQFSMZMFWFMFECFGPSF
QSPDFFEJOH
•
5IJTUSPVCMFTIPPUJOHHVJEFJEFOUJmFTTPNFCVUOPUBMMPGUIFQPTTJCMFDBVTFTGPSDPNNPOQSPCMFNTUIBUDBO
PDDVS
• Use this troubleshooting guide along with the appropriate
ELECTRICAL SCHEMATIC.
Valve Test Procedure
6TFBEJHJUBMNVMUJNFUFSUPNFBTVSFUIFSFTJTUBODFPGWBMWFDPJMT
.FBTVSFUIFSFTJTUBODFBDSPTTUIFWBMWFDPJMUFSNJOBMTXJUIUIFXJSJOHIBSOFTTEJTDPOOFDUFE3FWFSTFUIFNFUFS
MFBETPOUIFUFSNJOBMTBOENFBTVSFUIFSFTJTUBODFJOUIFPQQPTJUFEJSFDUJPO"SFTJTUBODFPGMFTTUIBOPINT
in either direction
JOEJDBUFTBTIPSUFEDPJM5IFWBMWFNVTUCFSFQMBDFE
*GBTIPSUFEDPJMJTOPUEFUFDUFEUFTUGPSBOPQFODPJM
3FDPOOFDUUIFWBMWFUFSNJOBMTUPUIFXJSJOHIBSOFTT
2
1PXFSVQUIFCSFXFSXJUIUIFBQQSPQSJBUFDPWFSSFNPWFEUPBMMPXBDDFTTUPUIFWBMWF
3
3VOBCSFXDZDMFXIJMFNPOJUPSJOHUIFWPMUBHFBUUIFWBMWFDPJMUFSNJOBMT*GWPMUBHFJTQSFTFOUPOUIFUFSNJOBMT
ZPVTIPVMEIFBSUIFWBMWFDMJDLPQFODMPTFEBUUIFNPNFOUQPXFSJTBQQMJFEPSSFNPWFEGSPNUIFUFSNJOBMT
5IFJOMFUWBMWFTIPVMEPQFOBOZUJNFUIFXBUFSUBOLJTOPUGVMM*GUIFWBMWFEPFTOPUPQFOSFQMBDFUIFWBMWF*G
WPMUBHFJTOPUEFUFDUFEmSTUDIFDLUIFXJSJOH*GUIFXJSJOHJT0,SFQMBDFUIF6$.
Water Not Hot Enough
*GUIFXBUFSIFBUTCVUJTOPUIPUFOPVHImSTUDIFDLGPSUIFDPSSFDUUFNQFSBUVSFTFUUJOHPOUIFDPOUSPMQBOFM
3FQSPHSBNBTOFDFTTBSZ
2
*GUIFUFNQFSBUVSFTFUUJOHJT0,BOEUIFBDUVBMXBUFSUFNQFSBUVSFEPFTOPUNBUDITFUUJOHPOUIFDPOUSPMQBOFM
replace the temperature sensor
Water Heats More Slowly Than Usual
$IFDLGPSQPXFSBDSPTTUIFUFSNJOBMTPGUIFIFBUJOHFMFNFOU T*GQPXFSJTCFJOHTVQQMJFEEJTDPOOFDUUIFIFBUJOH
FMFNFOU TBOEDIFDLGPSDPOUJOVJUZ3FQMBDFBIFBUJOHFMFNFOUJGUIFSFTJTUBODFJTUPPIJHI OPNJOBMSFTJTUBODFJT
0INT
2
*GUIFSFJTOPQPXFSUPUIFIFBUJOHFMFNFOU TDIFDLUIFXJSJOHUPBOZFMFNFOUUIBUEPFTOPUIBWFUIFQSPQFS
WPMUBHFBDSPTTJU"MTPDIFDLGPSDPSSPEFEDPOOFDUJPOTBOZXIFSFCFUXFFOUIFQPXFSDPSEBOEUIFIFBUJOH
FMFNFOU T
TROUBLESHOOTING GUIDE
TG5
(#3&8&345306#-&4)005*/((6*%&
ø
"
IMPORTANT:
*GJUJTOFDFTTBSZUPSFQMBDFUIF(VOJWFSTBMDPOUSPMNPEVMF 6$.
always
DIFDL
all
JOMFU
EVNQ CSFX CZQBTT BOE EJMVUJPO WBMWF DPJMT GPS B TIPSU BOE SFQMBDF UIF WBMWF BT OFDFTTBSZ CFGPSF
SFQMBDJOHUIFNPEVMF4FFUIF
Valve Test Procedure
CFMPXUPUFTUGPSEFGFDUJWFWBMWFT4PNFVOJUTEPOPU
IBWFUIJTGVODUJPOTFFUIF
ELECTRICAL SCHEMATIC