46 AXN Quick Start Kit User Guide (BK/0045 | 9 Aug. 2021)
3
Configuring the AXN/ADC/401 for AC coupled inputs
1.
Set the channel
Input Mode
to
AC coupled, single ended voltage
.
2.
Configure
Filter Mode
and
Filter Cutoff
for each filter tap point. (See
“Defining Filter Mode and Filter Cutoff for
.)
3.
Set the channel range to the required range for the AC coupled input.
4.
Set
Excitation Amplitude
to
0
.
Configuring the AXN/ADC/401 for ICP inputs
1.
Set the channel
Input Mode
to
ICP sensor
.
2.
Configure
Filter Mode
and
Filter Cutoff
for each filter tap point. (See
“Defining Filter Mode and Filter Cutoff for
.)
Summary of Contents for AXN