DuraCOR 311
Appendix C
– BIOS Settings
MNL-0667-01 Rev B2
ECO-5941
Effective: 17 Mar 20
Page 67 of 72
Memory ECC Error Logging
Feature
Options
Description
Error Logging
Disabled
Enabled
Enable Memory ECC Error Logging to
SMBIOS Event Log. Please note that
enabling ECC error logging is only
useful on systems equipped with ECC
memory. Changing the settings on a
non-ECC system will have no effect
- Single-Bit
Disabled
Enabled
Log single bit errors
- SECC Threshold
Disabled
Enabled
When the error times exceeds the
threshold counter every time, then to
record the event
- SECC Threshold Counter
20
Range from Min. to Max. (
⇐
65535)
- Multi-Bit
Disabled
Enabled
Log multi bit errors
- Halt on Uncorrectable Error
Disabled
Enabled
Controls whether to halt or not when
uncorrectable errors are encountered