background image

MHW 0002 – DK 1693  |  Version 001 – 14/09/2017  |  custo med GmbH

2

[2] Resting and Stress ECG hardware, custo cardio 200 | 

page 23

Resting and Stress ECG

 Hardware, description of device for custo cardio 200

Set no. 

Set name 

Part no. 

Qty. 

Set/product designation

85120 

custo cardio 200 BT 

 

 

   

 

85051 

custo cardio 200 BT

   

 

85034 

Thoracic wall leads

   

 

85035 

Extremity leads

   

 

85027 

2 pck.  electrode hair

   

 

85032 

Spacer 2-fold

   

 

85033 

Spacer 3-fold

   

 

85071 

Telescopic boom for cardio 200

   

 

85073 

Bracket for telescopic boom

   

 

85070 

Cable hook for cardio 200

   

 

55050 

LM506 (Bluetooth 4.0 USB adapter)

   

 

16018 

USB extension cable

   

 

85055 

Table power supply unit pulsed for

   

 

85044 

Power cable for power supply unit BT 1 m

   

 

85052 

USB cable 5 m

85110  

custo cardio 200

   

 

84022 

custo cardio 200 

   

 

85027 

2 pck.   electrode hair 

   

 

85034 

Thoracic wall leads

   

 

85035 

Extremity leads

   

 

85032 

Spacer 2-fold 

   

 

85033 

Spacer 3-fold 

   

 

85055 

Table power supply unit

   

 

85044 

Power cable for power supply unit BT 1 m

   

 

85052 

USB cable 5 m 

   

 

85071 

Telescopic boom for cardio 200

   

 

85073 

Bracket for telescopic boom

   

 

85070 

Cable hook for cardio 200 

Accessories   

Part no. 

Set/product designation

   

 

85027/Z 

Electrode “hair” (bag of 10 pieces)

   

 

85064/Z 

Electrode “standard” (bag of 10 pieces)

   

 

85065/Z 

Electrode “small” (bag of 10 pieces)

   

 

85035/z 

Extremity lead (1.45 m)

   

 

85034/z 

Thoracic wall lead (1.20 m)

   

 

85061 

Suction lead extra long (1.65 m)

   

 

85032 

Spacer 2-fold

   

 

85033 

Spacer 3-fold

   

 

85036/z 

Coding set (1 sheet of 10 pieces)

   

 

85070 

Cable hook for cardio 200

   

 

85071 

Telescopic boom for custo cardio 200

2.11

  List of product components and accessories

Summary of Contents for custo cardio 200

Page 1: ...ual Resting and Stress ECG Part 2 Hardware description of device for custo cardio 200 1 2 3 4 Safety Hardware Software Hygiene Operating characteristics 12 channel PC ECG Resting stress test ECG MHW 0...

Page 2: ...ted into another language without the prior written consent of custo med GmbH The manufacturer reserves the right to change the information in this Operating Manual without prior notice The current ve...

Page 3: ...the patient and examination procedure 12 2 6 Attaching the device to the patient electrode application 13 2 7 Instructions for the recording 14 2 8 Technical data and system requirements 16 2 9 Manuf...

Page 4: ...6 85521 Ottobrunn Germany CE mark Observe the Operating Manual Separate collection of electrical and electronic equipment do not dispose with domestic waste Safety class classification of medical ele...

Page 5: ...200 is a 12 channel PC ECG device with an electrode application sys tem designed for the creation analysis and evaluation of ECG recordings in medical practices and hospitals The system is intended fo...

Page 6: ...ts list for the flash cardio 200 sets custo cardio 200 USB version or custo cardio 200 BT Bluetooth version Electrode hair 2 bags of 10 pieces Thoracic wall leads 1 20m 6 pieces Extremity leads 1 45m...

Page 7: ...Suction lead extra long 1 65m Spacer 2 fold Spacer 3 fold Coding set sheet of 10 pieces Cable hook for electrode leads Telescopic boom Telescopic boom short for custo easy plus device trolley Bracket...

Page 8: ...ing Extraction lock to extend and pull in the boom arm Bracket for custo cardio 200 with safety bar Position the clamps and and secure them with an Allen key size 5 mm Mount the clamps straight aligne...

Page 9: ...securely move the device trolley with the telescope boom fix the telescope boom tighten the locking device set the angle of the boom arm to 90 degrees height adjustment push the lever and simultaneous...

Page 10: ...ching the electrode leads Attach the coding labels to the ends of the electrode leads The labels C1 to C6 are glued to the chest wall leads length 1 20 m The labels R L F and N are glued to the longer...

Page 11: ...yed Automatic control of the suction level If the suction level is adjusted manually with the and keys the automatic control of the suc tion level of the device will be deactivated If automatic suctio...

Page 12: ...the PC and the power supply to the device is guaranteed When using an ergometer make sure that the patient is in the optimal seating position the extended leg should be slightly bent When using a tre...

Page 13: ...V4 C4 brown 5th intercostal space on the left midclavicular line V5 C5 black on the left hand side of the anterior axillary line at the same height as C4 V6 C6 purple on the left hand side of the mid...

Page 14: ...e ECG signal Missing skin tension in interaction with shoulder movement will increase artefacts in the ECG signal The extremity leads should if possible be applied on taut skin areas in order to avoid...

Page 15: ...treadmill so that the patient can safely move on the device Ensure that the acceleration speed and inclination of the treadmill are adjusted to the patient s physical constitution stamina and skill O...

Page 16: ...Level 5 220 mbar Level 6 280 mbar Power supply 15V DC Use only the supplied power supply unit part no 85055 Energy consumption max 25 Watt during recording IT connection USB cable length 5 m or Blueto...

Page 17: ...ws 7 SP1 with current updates 32 bit and 64 bit operating system Windows 8 32 bit and 64 bit operating system Windows 8 1 32 bit and 64 bit operating system Windows 10 32 bit and 64 bit operating syst...

Page 18: ...scharge 2 kV for net wires 1 kV for input and output wires 1 kV push pull voltage 2 kV push push voltage 5 UT for 0 5 periods 95 drop 40 UT for 5 periods 60 drop 70 UT for 25 periods 30 drop 5 UT for...

Page 19: ...e device is used the device should be watched in order to prove the intended functions If unusual performance features are observed it may be necessary to take additional meas ures for example reorien...

Page 20: ...ed below For transmitters whose maximum nominal power is not indicated in the above table the recommended protec tive distance d can be determined in meters m using the equation affiliated with the co...

Page 21: ...1693 Version 001 14 09 2017 custo med GmbH 2 2 Resting and Stress ECG hardware custo cardio 200 page 21 Resting and Stress ECG Hardware description of device for custo cardio 200 2 10 EC Declaration o...

Page 22: ...MHW 0002 DK 1693 Version 001 14 09 2017 custo med GmbH 2 2 Resting and Stress ECG hardware custo cardio 200 page 22 Resting and Stress ECG Hardware description of device for custo cardio 200...

Page 23: ...t BT 1m 85052 1 USB cable 5m 85110 custo cardio 200 84022 1 custo cardio 200 85027 2 pck electrode hair 85034 6 Thoracic wall leads 85035 4 Extremity leads 85032 2 Spacer 2 fold 85033 2 Spacer 3 fold...

Page 24: ...ce trolley 85073 Bracket for telescopic boom including fixtures 85068 Universal bracket for custo cardio 200 85079 Wall mounting set for cardio 200 85055 Power supply unit for cardio 200 BT small 8504...

Page 25: ...Manufacturer s contact details custo med GmbH Maria Merian Stra e 6 85521 Ottobrunn Germany Phone 49 0 89 710 98 00 Fax 49 0 89 710 98 10 E mail info customed de Internet www customed de...

Reviews: