MHW 0010 – DK 1696  |  Version 001 – 21/09/2017  |  custo med GmbH

2

[2] Cardiac Rehabilitation hardware, custo guard (custo cardio concept) | 

page 19

Cardiac Rehabilitation

 Hardware, description of device for custo guard (custo cardio concept)

Manufacturer’s declaration – electromagnetic immunity

The custo guard ECG transmitter is designed for use in the electromagnetic environment stated below. The cus-

tomer or user of custo guard should make sure that it is used in such an environment.

COMMENT 1: 

With 80 MHz and 800 MHz the higher frequency range is valid. 

COMMENT 2:

These guidelines may not apply in every case. The propagation of electromagnetic variables is influenced by ab-

sorptions and reflections of buildings, objects and people.

a)

 The field strength of stationary transmitters, such as e.g. base stations of mobile phones and land mobile radi-

os, amateur radio stations, AM and FM broadcasting as well as television networks cannot be exactly predeter-
mined theoretically. In order to determine the electromagnetic environment regarding the stationary transmit-

ters, a study of the location should be considered. If the measured field strength exceeds the above-mentioned 

compliance levels at the location where custo guard is used, the device should be watched in order to prove the 
intended functions. If unusual performance features are observed, it may be necessary to take additional meas-
ures, for example reorienting or relocating custo guard.

b)

 Within the frequency range of 150 kHz to 80 MHz, the field strength should be less than 10 V/m.

Immunity tests

Conducted HR disturbances

according to IEC 61000-4-6

Radiated HR disturbances

according to IEC 61000-4-3

IEC 60601 test level

3 V

effective value

150 KHz to 80 Mhz 

3 V/m

80 MHz to 2.5 GHz

Compliance level

[U

1

] V

Not applicable

E

1

 = 10 V/m

Electromagnetic environment - guidelines

Portable and mobile radio sets should not be used at a 

closer distance to custo guard including the leads than 

the recommended protective distance which is deter-

mined according to the equation applicable to the fre-

quency of the transmitter.

Recommended protective distance:

d = [3.5/U

1

)] √P

d = [3.5/E

1

] √P 

for 80 MHz to 800 MHz

d = [7/E

1

] √P 

for 800 MHz to 2.5 GHz

with P as the nominal power of the transmitter in watt 

(W) according to the indications of the transmitter man-

ufacturer and d as the recommended protective distance 

in meters (m).

According to an examination on-site 

a) 

the field strength 

of stationary radio transmitters should be inferior to the 

compliance level 

b) 

with regard to all frequencies.

In the vicinity of devices carrying the following symbol, 

interference is possible: 

Summary of Contents for Custo Guard 1/3

Page 1: ...ilitation Part 2 Hardware description of device for custo guard custo cardio concept 1 2 3 4 Safety Hardware Software Hygiene Operating characteristics 1 3 channel ECG Cardiac rehabilitation MHW 0010...

Page 2: ...anufacturer reserves the right to change the information in this Operating Manual without prior notice The current version can be downloaded from our web site www customed de CAUTION This Operating Ma...

Page 3: ...ing position on the ergometer 11 2 5 3 Blood pressure cuff 11 2 5 4 Adjusting the length of the custo belt 3 for 3 channel ECG 12 2 5 5 Attaching custo guard 1 without an electrode belt to the patient...

Page 4: ...ept IP65 Manufacturer custo med GmbH Maria Merian Str 6 85521 Ottobrunn Germany CE mark Observe the Operating Manual Separate collection of electrical and electronic equipment do not dispose with dome...

Page 5: ...ply that transmits the data by radio waves custo guard is used in cardiac rehabilitation for wireless patient monitoring The ra dio transmission allows continuous monitoring of patients independent of...

Page 6: ...uard 1 sets parts list custo guard 1 set custo guard 1 1 channel ECG transmitter custo belt 1 red 1 channel electrode belt custo belt 1 3 extender extension piece for the electrode belt Adapter set fo...

Page 7: ...ard 3 set parts list custo guard 3 set custo guard 3 3 channel ECG transmitter custo belt 3 red 3 channel electrode belt custo belt 1 3 extender extension piece for the electrode belt Adapter set for...

Page 8: ...for an ECG transmitter Power supply unit for custo charger single and custo charger multi custo charger multi set custo charger multi charger for six ECG transmitters Power supply unit for custo charg...

Page 9: ...can occur that an ECG transmitter that is indicated to be completely charged green LED shows the status Charging red LED again if it is removed and then reinserted into the charger Rechargeable batter...

Page 10: ...lectrode belt The skin must be free from grease and personal care products The electrode belt must be set up so that it fits tightly and the contact surfaces make good contact but that the patient is...

Page 11: ...eir arms crossed over their chest for example Before starting the exercise always check the ECG in the exercise station over view in custo diagnostic and perform measures to improve the ECG if necessa...

Page 12: ...The length adjustment slider is located directly next to the point where the material becomes wider on the custo belt The elastic excess length is completely pulled through the slider so that the slid...

Page 13: ...maximum length is not sufficient use a custo belt extender extension piece The custo belt extender is adjusted to the minimum length when the slider is locat ed next to the material loop The maximum...

Page 14: ...the cable adapters Place the ECG transmitter in the case and close the case Attach the neck strap to the case Adjust the neck strap to the desired length Clean the electrode application points the ski...

Page 15: ...to guard ECG trans mitter onto the 4 contact points Attach the neck strap to the hooks on the custo ECG cable guard 3 Adjust the neck strap to the desired length Clean the electrode application points...

Page 16: ...re 20 C 40 C conditions Air humidity 10 95 rH Air pressure 700 1060 hPa Classification Device with internal power supply Class IIa Type BF DIN EN 60601 1 DIN EN 60601 2 47 Holter standard as far as ap...

Page 17: ...ing system Windows 7 SP1 with current updates 32 bit and 64 bit operating system Windows 8 32 bit and 64 bit operating system Windows 8 1 32 bit and 64 bit operating system Windows 10 32 bit and 64 bi...

Page 18: ...e directly con nected to the public low voltage power supply network that also supplies buildings used for domestic purposes Immunity tests Electrostatic discharge ESD according to IEC 61000 4 2 Fast...

Page 19: ...custo guard is used the device should be watched in order to prove the intended functions If unusual performance features are observed it may be necessary to take additional meas ures for example reor...

Page 20: ...ated below For transmitters whose maximum nominal power is not indicated in the above table the recommended protec tive distance d can be determined in meters m using the equation affiliated with the...

Page 21: ...21 09 2017 custo med GmbH 2 2 Cardiac Rehabilitation hardware custo guard custo cardio concept page 21 Cardiac Rehabilitation Hardware description of device for custo guard custo cardio concept 2 8 E...

Page 22: ...1696 Version 001 21 09 2017 custo med GmbH 2 2 Cardiac Rehabilitation hardware custo guard custo cardio concept page 22 Cardiac Rehabilitation Hardware description of device for custo guard custo car...

Page 23: ...custo guard 3 10302 1 custo guard 3 10301 R 1 custo belt 3 red for custo guard 3 10118 1 custo belt 1 3 extender for custo guard 1 3 Accessories Part no Set product designation 10118 custo belt 1 3 e...

Page 24: ...Manufacturer s contact details custo med GmbH Maria Merian Stra e 6 85521 Ottobrunn Germany Phone 49 0 89 710 98 00 Fax 49 0 89 710 98 10 E mail info customed de Internet www customed de...

Reviews: