CC650
Production / Industrial Hose Crimper
10
AccuCrimp ACT
TM
CONTROL PANEL QUICK START
While the ACT
TM
crimper has the ability to perform a number of
fully automatic functions, manual operation is also possible.
To make a manual crimp, two numbers are needed:
The closed diameter of the die
(in either inches or mm).
The fi nished crimp diameter
(in either in or mm)
That’s all you need to know. ACT
TM
does the rest.
TO MAKE A MANUAL CRIMP:
• Press
START Button
.
• Select
CRIMP TO DIAMETER.
• Enter the closed diameter of the die set in either in or mm
and
press
ENTER
.
Note: for a 25mm die, enter 2500.
ACT
TM
will add the decimal point.
Decimal point entry:
For 1.56 inch entry, enter 1560 (Controller supplies 3
places for entries in inches).
For a 50.0 mm entry, enter 5000 (Controller will supply 2
decimal places for entries in mm).
•
Enter the fi nished crimp diameter and press
ENTER
.
• From
the
ENTER CRIMP
screen, press the
MANUAL
button
to put the crimper in manual mode.
• Confi rm that the die and fi nished crimp diameters are correct
and
that
MANUAL MODE
is displayed.
• Press and hold the green
CLOSE
button until the crimper
stops
closing.
• Check
the
fi nal crimp diameter. If a minor correction is
required
see
HOW TO MAKE MINOR CORRECTIONS.
Tip: Pressing the CHANGE DIES button allows the crimper
head to be fully opened or closed with the green OPEN-CLOSE
buttons on the controller front panel When the CHANGE DIES
button is blinking the dies can be opened and closed manually
without altering any of the crimper settings
.
Note:
When using the overbore (OB) dies you must
use the SAVED DIE feature. Press the
USE SAVED
DIE
to select the correct die set from the die memory
table.