PLC RESET PROCEDURE
PLC RESET PROCEDURE:
The PLC (Programmable Logic Controller) requires a relatively constant source of electrical power. Power surges, outages or
drops in power can cause the PLC to lose its settings. This may result in missing or misplaced information on the controller
screen
.
RESETTING THE PLC TO ITS ORIGINAL SETTINGS IS A SIMPLE PROCEDURE:
• Open the front of the Control Panel.
• Power up the crimper from the main power switch. The crimper must be powered on during the PLC reset procedure.
• Move the three position toggle switch on top of the PLC right to the STOP position and then left to the RUN position.
• Return the toggle switch to the center TERM position.
• Repeat for the other PLC Unit.
• Cycle the main power off and back on.
• The PLC and the crimper should now operate normally.
• Close the control panel.