CC650
Production / Industrial Hose Crimper
5
INITIAL SET UP
• Check the oil level in the sight glass gauge on the front of the
reservoir.
• 24 U.S. gallons of ISO 46 hydraulic oil is required to completely
refi ll the reservoir.
Note:
Oil can be drained from either of the two ports at the rear bottom
of the reservoir.
An additional oil cooler, while not normally required, can be plumbed
into the two ports at the rear bottom of the reservoir.
• Check electrical circuit to be certain that it matches to the crimper
requirements as shown on the voltage decal on the electrical
enclosure.
Electrical Requirements:
7.5HP/230V/3Phase (20 Amp)
7.5HP/440V-480V/3Phase (20 Amp)
5HP/230V/1Phase (30 Amp)
• Plug the cord directly into the appropriate wall outlet.
Caution:
Do not run the crimper on an extension cord as low voltage
can damage the motor and / or electrical components.
• Check to be certain that the motor rotates in the direction of the
arrow shown on the motor housing.
• If motor rotation is incorrect reverse any two hot wires in the crimper
plug.
(Note: This is applicable to 3 phase circuits only)
Note:
Damage to the pump can result if the motor does not rotate in
the correct direction.