Step 4:
Place the
Lubricated Die Set
squarely in the cone base.
Note:
Make sure the split of the die cages is facing the operator.
(as shown).
Step 6:
Place the
Lubricated Standard Pressure Plate
over the die set.
Step 5:
Align the fi tting in the die set according to the hose and fi tting
manufacturer’s recommendation.
Note:
Compress the die set by hand to hold the hose and fi tting in place.
CRIMPING WITH
STANDARD
T420 PRESSURE PLATE