D105-T420 SERIES
Service Hose Crimpers
17
CALIBRATION CHECK PROCEDURE
THE CRIMPER IS CALIBRATED PRIOR TO SHIPMENT, BUT A
CALIBRATION CHECK IS RECOMMENDED PRIOR TO USING
THE CRIMPER FOR THE FIRST TIME.
Note:
Follow the lubrication procedure prior to calibration check.
CAUTION:
Failure to lubricate the die set and pressure plate could
result in the die seizing in the cone base.
Step 1:
Make certain that the
Cone Base
is clean and lubricated prior to
inserting the die set.
Step 2:
Place
Any Lubricated Die Set
squarely in the cone base.
Note:
Make sure the split of the die cages is facing the operator.
(as shown).
Step 3:
Place the
Lubricated T420 Pressure Plate
over the die set.
Note:
A hose and fi tting are not required for a calibration check.