Page 10 of 44
Burner Construction
Take some time to review the burner construction taking note of the positions
of the main components and connections.
WARNING:
Removal of the connections from the remote system or the
grommets marked “Electric Supply” or “Hard Wire switch lead” as
shown in the burner construction drawings will result in the warranty
being invalidated. No claims will be accepted for damage caused by the
burner being tampered with. All CVO fires are given a 100% full
function test at the factory and are very reliable hence there is no need
to remove any fittings.
Before commencing to create the fire opening for the inglenook unit, Note to
maintain a good standing pressure we recommend that a 15mm supply be
piped in as close as possible with a reduction down to 8mm diameter copper
pipe (no longer that 2m in length – gas supply to the burner unit) must be
installed, the gas supply pipe should run into the installed enclosure from either
the rear, left or right hand sides, the gas supply is best run through the left
side of the enclosure.
Additionally a 240volt 3amp fused spur power supply should be installed. This is
best fitted so that the power supply is located to the right side of the unit. This
will provide the power source for the remote control system.
NOTE – DO NOT connect power to the hardwired switch as this will
damage the remote control system.
There are yellow labels attached to the
cables please follow the information.
Burner Removal
Removal of the burner will invalidate the warranty. If the burner needs
to be removed for repair follow the below steps:
•
Remove the front shelf.
•
Remove the 2 screws on each side which hold the shelf mounting
brackets to the enclosure.
•
Disconnect the gas and electricity supply.
•
The burner carriage is screwed to the bottom of the enclosure by 2
screws. Once removed the full burner assembly will lift out.
•
Refit is the same procedure in reverse.
•
The fire should be commissioned once refitted.
Summary of Contents for Fire River
Page 4: ...Page 4 of 44 ...
Page 8: ...Page 8 of 44 Component List Specification ...
Page 9: ...Page 9 of 44 ...
Page 11: ...Page 11 of 44 LPG Version Natural Gas Version ...
Page 19: ...Page 19 of 44 Magic Eye Position ...
Page 24: ...Page 24 of 44 The Remote Control Black Box Remote Valve NG Version LPG Version ...
Page 26: ...Page 26 of 44 SEAGAS PILOT ASSEMBLY ...
Page 27: ...Page 27 of 44 Remote Wiring Diagram With SIT Pilot ...
Page 28: ...Page 28 of 44 Remote Wiring Diagram with SEAGAS Pilot ...
Page 32: ...Page 32 of 44 ...
Page 33: ...Page 33 of 44 PIN NUMBER 0558CN1404 Rev 10 Fire River USER HANDBOOK ...
Page 39: ...Page 39 of 44 Infra Red Remote Replacing the Battery ...
Page 43: ...Page 43 of 44 ...