Page 25 of 44
Pilot Assembly / Spark Failure
The gap between the pilot electrode and the pilot should be 3.5 – 4.5mm and
normally adjustment is not necessary (the electrode is very brittle). The spark
should jump across the gap between the electrode and the gas outlet on the
pilot head. If the ignitor fails, a lighted taper can be inserted into the pilot area
to check that gas is reaching the pilot.
SIT 9103 / SIT 9272 PILOT ASSEMBLY
Summary of Contents for Fire River