Page 7 of 44
Power Supply
Read through this section before starting the installation
The installation should only be carried out by a CORGI registered
installer and in accordance with national and local regulations for
both gas and electricity
.
Power Supply
230v AC-15%+10%, 50/60 Hz
Max power consumption
20VA cos 0.6 (Peak)
Stand-by power consumption
1W
Ambient Temperature
0.80 C
Protection IP
20
Humidity
Max 95% at 40c
Electrical protection
Not required
Connections STELVIO/STOCKO
Waiting time for demand
3-5 seconds typically
Ignition Time
20 seconds typically
Ignition Frequency
1Hz
Spark gap
Max 6mm
Ignition Cable length
500mm
The black lead is the electrical feed to the burner, a 3 amp fused spur located
wherever convenient is to be connected between the power supply and the
burners black lead. The Grey or white wire is connected to the
hardwire
switch
which if used, can be positioned as required. NOTE- DO NOT connect
the Hardwire switch to the mains, as this will damage the unit.
A mains connection is required close to the fireplace-a 0.7m cable is provided
for this purpose with a special plug connected to the burner control box. A
3amp socket may be used, or a fused spur outlet can be purpose provided.
The colour code of the mains is as follows;
Green/Yellow
-
EARTH
Brown -
LIVE
Blue
-
NEUTRAL
The appliance must be in a position so that the mains supply is accessible for
routine maintenance.
A 3amp fused should be fitted in the plug of fused spur.
WARNING – This appliance must be earthed.
Summary of Contents for Fire River
Page 4: ...Page 4 of 44 ...
Page 8: ...Page 8 of 44 Component List Specification ...
Page 9: ...Page 9 of 44 ...
Page 11: ...Page 11 of 44 LPG Version Natural Gas Version ...
Page 19: ...Page 19 of 44 Magic Eye Position ...
Page 24: ...Page 24 of 44 The Remote Control Black Box Remote Valve NG Version LPG Version ...
Page 26: ...Page 26 of 44 SEAGAS PILOT ASSEMBLY ...
Page 27: ...Page 27 of 44 Remote Wiring Diagram With SIT Pilot ...
Page 28: ...Page 28 of 44 Remote Wiring Diagram with SEAGAS Pilot ...
Page 32: ...Page 32 of 44 ...
Page 33: ...Page 33 of 44 PIN NUMBER 0558CN1404 Rev 10 Fire River USER HANDBOOK ...
Page 39: ...Page 39 of 44 Infra Red Remote Replacing the Battery ...
Page 43: ...Page 43 of 44 ...