Digital Temple Thermometer
INSTRUCTIONS FOR USE
Please read carefully before using
KD-2270
IMPORTANT!
Read instruction manual before using the thermometer
Quick Start
1. Install batteries into the thermometer. Make sure the polarity is correct.
2. Press and release the POWER button. Unit will beep once. Wait until it beeps again
twice and °F appears in the display.
3. Place and hold the thermometer probe firmly to the skin at the temple and wait
several seconds for the device to beep once more.
4. Read the temperature on the display.
CLEANING AND CARE
1. Please do not drop the unit of expose to heavy shock. The unit is not shock proof.
2. Wipe the tip and probe with an alcohol swab or cotton swab moistened with 70%
isopropyl alcohol before & after each use. After cleaning, wait at least 2 minutes before
taking a measurement for the unit to readjust to room temperature.
3. Use only a soft dry cloth to clean the body of the thermometer (if necessary). Please
avoid thinner and benzene or other harsh
4. Please remove the battery if the unit will not be used for a long period.
5. Do not expose the thermometer to extreme temperatures, humidity, direct sunlight or
shock. Store it at room temperature.
LIMITED WARRANTY
Warranty:
The device itself (battery excluded) comes with one year warranty from purchasing date if
it is operated under normal circumstances without evidence of tampering. See exclusions
below.
Warranty exclusions:
1. If user does not properly operate the device according to the instructions as described
in this manual.
2. If the device shows signs of tampering or attempted modification.
3. Improper handling, such as dropping, liquid or cleaner damage.
4. Natural disasters (such as fire, flood, earthquake, lightning strike).
5. If you do not have a receipt or proof of purchase showing date of purchase.
LOT NUMBER INFORMATION
YYMM on the device label means the year and month of manufacturing. For example,
"1810" means the unit was manufactured in October, 2018.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
● Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Radiation Exposure Statement:
The product comply with FCC portable RF exposure limit set forth for an uncontrolled
environment and are safe for intended operation as described in this manual. The further
RF exposure reduction can be achieved if the product can be kept as far as possible from
the user body or set the device to lower output power if such function is available.
Changes or modifications not expressly approved by 180 INNOVATIONS may void the
user's authority to operate this devise.
Distributed by : CVS pharmacy,Inc
One CVS Drive Woonsocket,RI 02895
1-800-shop-CVS www.cvs.com
Manufactured by:
180 INNOVATIONS LAKEWOOD,CO80215 and K-jump Health Co.,Ltd.
Made in China
www.180innovations.com
MEMORY MODE
Recalling Memories:
1. Turn off the unit first.
2. Press the POWER button and hold for 3 seconds until the last record is shown.
3. Press the POWER button to choose previous reading.
4. After the POWER button is released, you will hear 2 beeps indicating ready to measure.
Deleting Memories:
1. In Recalling Memories step, press the POWER button again and hold for 3 seconds
until “dEL”
shows .
2. Press the POWER button to delete all memories then the thermometer will power off
automatically.
3. If you don’t press the POWER button, the thermometer will return to
Recalling
Memories
step.
5. Put the thermometer on the temple then it beeps one time to present measurement
completion.
6. If the temperature reading is over 99.5°F (37.5°C), eight consecutive beeps will be
heard to indicate fever alarm.
7. Once the measurement is done and the reading is recorded then you will hear 2 beeps
for ready to take the next measurement.
8. Turn off the unit by pressing the POWER button, or the unit will automatically turn off
after 60 seconds of inactivity .
9. Switching between Centigrade and Fahrenheit:
Turn unit on. While 188.8 is still showing press & hold the power button again for 2
seconds.
Waiting
Ready for the next measurement
1. Install 2 AAA batteries.
2. Press the POWER button to turn on the unit. A beep sound follows.
3. The last memory is displayed .
4. You will hear 2 beeps with the measuring scale shown as following figures.
HOW TO USE
Power On
Loading
Ready to test
TROUBLESHOOTING
The Temperature measured was highter than the specified measuring range.
Please measure again.
The ambient (room) temperature was outside the operating range. Keep it at
room temperature (approx. 60.8°F~104°F) for 30 minutes before using.
Poor contacts cause the thermometer stop to measure. The thermometer will
power off automatically. Please contact distributor.
Low battery indication, replace two AAA batteries.
The thermometer is no function. Please contact distributor.
EXPLANATION OF SYMBOLS
Manufacturer
Power Button
Warning and Caution
Low battery indication
Waiting for setting
Place on the temple to do measurements
MMYY
: Lot Number composed by month(M) and year(Y) of manufacture
BATTERY REPLACEMENT
1. Take the battery cover off in the direction shown.
2. Install 2 new AAA batteries into thermometer.
3. Re-place the battery cover securely.
Warning :
1. Do not put used batteries in trash.
2. Recycle or manage used batteries as hazardous waste.
3. Never dispose of batteries in fire.
4. Dispose of used batteries in recycling trash only.
5. Do not recharge, put in backwards or disassemble. This may cause explosion,
leakage and injury.
6. Memory may be erased after replacing a new battery.
Read-back last memory by NFC
Install OUcare APP from Google play or App Store successfully. OUcare not only collect
temperatures but also can do graph for checking temperature’s trend easily.
For Android mobile device : When the device is off,
put mobile device above the thermometer, the last
temperature will be read-back and show on mobile
device.
For iPhone7 or above : The iOS should be 11.0 or
above. When the device is off, press the icon
of APP then close to the thermometer, the last
temperature will be read-back and show on mobile
device.
Right side is a figure of NFC area of iPhone7.
PRECAUTION
1. Use the thermometer to measure your temple temperature only, the place between the
eyehole and the hairline, close to the temporal artery.
2. Do not place the thermometer on scarred tissue, open sores or abrasions.
3. Using drug therapies may raise forehead temperature, which may lead to incorrect
measurements.
4. Do not dismantle the unit unless replacing the batteries.
5. Children should not use the thermometer if being alone, without supervision of adults.
6. The thermometer is not shock proof. Do not drop the thermometer or shock it heavily.
7. The thermometer is not water proof. Do not immerse it in liquid of all kinds including
water.
8. To ensure correct readings, please wait for at least 2 minutes between continuous
measurements for the thermometer to return to room temperature.
9. Do not use the thermometer when flammable materials are around.
10. Stop using the thermometer once malfunctions appear or it operates abnormally.
11. Clean the thermometer probe before measuring.
12. Do not take measurement of temple skin if it is exposed to direct sunlight, fireplace
heat and air conditioner flow, as this may lead to incorrect readings.
13. If thermometer has been put at below-freezing temperatures, please wait for at least 1
hour for it to return to room temperature before measuring.
14. Being operated or stored outside the stated temperature and humidity ranges and
measuring the patient whose temperature is below the room temperature may
degrade the performance of the thermometer.
15. Body temperature, like blood pressure, varies from person to person, and during the
day, it may range from 35.5°C to 37.8°C (95.9°F to 100.0°F). For some people it may
show some difference from their normal temple temperature. It is recommended to
learn and recognize the temple temperature while healthy. For accurate results,
measure the same area of the temple each time of measuring.
16. Avoid taking measurement within 30 minutes after physical exercise, bathing or
eating.
17. Keep the temporal area dry and clean from sweat, make-up, etc.
18. Calibration is recommended every two years.
19. Follow the national requirement to dispose unit.
PARTS DESCRIPTION
Probe
Battery Cover
LCD Display
POWER Button
What are normal temperature values?
Human body temperature varies from person to person. One person's body temperatures
are different from time to time as well. Therefore, it is very important to know your normal
body temperature range. Thus we recommend you measure yourself when healthy to
establish referenced temperatures which will make you feel more confident of the
measured temperature when ill.
RE
V.20190808
PN.82227000XX
SPECIFICATIONS
Measurement Time
6 seconds
Measurement Range
95.0°F~107.6°F
Operating Condition
60.8°F ~ 104°F,
R.H. of 15~95% non-condensing
Storage Condition
-4°F ~ 120°F,
R.H. of 15~95% non-condensing
Measuring unit
°F
Accuracy
Less than 96.4
°F, Greater than 106.0°F
:
±0.5°F
96.4
°F
to less than 98.0
°F, Greater than 102.0°F to 106.0°F
:
±0.3°F
98.0
°F to 102.0°F
:
±0.2°F
Battery
AAA battery x 2pcs
NFC
Last memory read-back
iPhone7 and above
Android mobile device with NFC
Battery Life
More than 500 measurements.
Weight
Approx. 52g includes bat/- 5%
Dimension
127.7mm x 35.2mm x
33.4mm +/- 2%
Memory Set
9 sets
Auto Shut Off
After 60 seconds of inactivity
Warranty
1 year
ISO 13485
ASTM E1112
Certification
Measurement Site
Temples
Resolution
0.1°F