Operating instructions Multi-cell compressor RKL 160
Technical data
16
3 Technical data
General data
Unit
RKL 160
Weight RKL 160
[kg]
33
Rated speed
[1/min]
1500
Sound pressure level at final overpressure = 2.0 bar
1)
[dB(A)]
75
1) Distance to RKL 160 = 7 m
Tab. 1: General data
Permissible working range
Unit
RKL 160
Speed range
[1/min]
1200…1600
Suction temperature
1)
[°C]
-10…+40
Geodetic height
1)
[m]
0…1000
Vacuum suction side
[mbar]
0…65
Maximum final overpressure at the pressure flange
2)
[bar]
2.5
1) Consult CVS for suction temperature and/or altitudes outside the permissible working range.
2) Intake pressure at the suction flange = 1 bar, suction and ambient temperature = 20 °C
Tab. 2: Permissible working range
Performance characteristics at 1500 1/min
Unit
RKL 160
Suction volume flow at final overpressure
0.0 bar
[m
3
/h]
145
2.0 bar
115
Coupling output at final overpressure
0.0 bar
[kW]
4.5
2.0 bar
8.1
1) Intake pressure at the suction flange = 1 bar, suction and ambient temperature = 20 °C
Tab. 3: Performance characteristics at rated speed