Replace the soldering iron head

Change set temperature

A. Always turn off the power every time you remove or insert the soldering iron.

B. Place the soldering iron tip on the soldering iron head bracket.

C. Insert the new soldering iron head into the end.

If not fully inserted, a sensor error  S-E  will be displayed when the power is 

turned on.

example:

     If the measured temperature is 395 degrees Celsius, the temperature difference 

is +5 degrees Celsius and the soldering iron head is slightly colder than five degrees, 

so the correction is +5 degrees Celsius.

      If the measured temperature is 405 degrees Celsius, the temperature difference 

is -5 degrees Celsius, the soldering iron head is slightly hot five degrees, so the 

correction value is -5 degrees Celsius.

When changing from 350 degrees Celsius to 400 degrees Celsius.

Example: 

1. Insert the card into the card hole.

The leftmost digit (the third digit) will flash. Electric soldering

The station temperature is in the setting mode and the third digit can be adjusted.

2. The third digit of input

Select the number you want to replace the third digit. Use the "up" "down" button 

to change the display number to 2, 3, 4.(4, 5, 6, 7, 8 in Fahrenheit mode)

3. Input of the number of digits

Use the up or down buttons to determine the number of second digits. The 

number that can be entered is from o to 9 whole. After the desired number is 

displayed, press the * button. The rightmost number (first digit) starts to flash.

4. The first digit of the input

Use the up or down button to set the desired number. After the desired number 

is displayed, press the * button. This will exist in the internal memory, and after 

the new set temperature is displayed, the heating element control will be 

started.

Make sure that the card is inserted into the card hole in the correct orientation. 

When the temperature is set, the heating element is powered off.

If the power switch is turned off while the temperature is set, the set number will 

not be stored in the memory. The entire program must come from one.

When the console is ON and the card is inserted in the control , the numerical 

input procedure is as follows:

a. Press the head button for at least one second.

b. Display the current temperature set value, then the hundred digits start to flash 

    indicating that the console has entered the temperature setting mode.

c. Continue the procedures 1 to 4 above.

The set temperature will be displayed if the pressed button is pressed for less 

than 1 second.

Parameter setting

When the 942T is shipped from the factory, it has the preset 

values as follows:

Temperature unit
Automatic power off
Lowest limit setting temperature
Supervisor or operator correction limit
Factory Setting temperature

Celsius
none
150 degrees Celsius
40
350 degrees Celsius

Supervisor or operator correction limit setting

● When the console enters the low temperature alarm limit setting mode, the

   hundreds of digits starts to flash. Enter and store the set value in the same way as
   described in "Changing the Temperature Settings".

● If the input value exceeds the limit shown on the left, the system will jump back to

   the input of the hundred digits. You must re-enter the correct value at this time.

(1.)

(2.)

● Once the value is saved, the system will automatically proceed with the supervisor 

   or operator correction limit setting.

To change the supervisor or operator correction limit settings, the procedure 

is as follows:

● When you enter this mode, the display will show  40  or  41  .

If the card is not inserted, the soldering iron head correction value cannot be input.
If the card is not inserted, you can enter the soldering iron head correction value.

40
41

Press the  UP  or  down  button to select the area and press the        button. The 

system leaves the parameter setting mode and begins to control the heater to be 

energized. Normal operation is now possible.