note
note
note
Replace the soldering iron head
Change set temperature
A. Always turn off the power every time you remove or insert the soldering iron.
B. Place the soldering iron tip on the soldering iron head bracket.
C. Insert the new soldering iron head into the end.
If not fully inserted, a sensor error S-E will be displayed when the power is
turned on.
example:
If the measured temperature is 395 degrees Celsius, the temperature difference
is +5 degrees Celsius and the soldering iron head is slightly colder than five degrees,
so the correction is +5 degrees Celsius.
If the measured temperature is 405 degrees Celsius, the temperature difference
is -5 degrees Celsius, the soldering iron head is slightly hot five degrees, so the
correction value is -5 degrees Celsius.
When changing from 350 degrees Celsius to 400 degrees Celsius.
Example:
1. Insert the card into the card hole.
The leftmost digit (the third digit) will flash. Electric soldering
The station temperature is in the setting mode and the third digit can be adjusted.
2. The third digit of input
Select the number you want to replace the third digit. Use the "up" "down" button
to change the display number to 2, 3, 4.(4, 5, 6, 7, 8 in Fahrenheit mode)
3. Input of the number of digits
Use the up or down buttons to determine the number of second digits. The
number that can be entered is from o to 9 whole. After the desired number is
displayed, press the * button. The rightmost number (first digit) starts to flash.
4. The first digit of the input
Use the up or down button to set the desired number. After the desired number
is displayed, press the * button. This will exist in the internal memory, and after
the new set temperature is displayed, the heating element control will be
started.
Make sure that the card is inserted into the card hole in the correct orientation.
When the temperature is set, the heating element is powered off.
If the power switch is turned off while the temperature is set, the set number will
not be stored in the memory. The entire program must come from one.
When the console is ON and the card is inserted in the control , the numerical
input procedure is as follows:
a. Press the head button for at least one second.
b. Display the current temperature set value, then the hundred digits start to flash
indicating that the console has entered the temperature setting mode.
c. Continue the procedures 1 to 4 above.
The set temperature will be displayed if the pressed button is pressed for less
than 1 second.
Parameter setting
When the 942T is shipped from the factory, it has the preset
values as follows:
Temperature unit
Automatic power off
Lowest limit setting temperature
Supervisor or operator correction limit
Factory Setting temperature
Celsius
none
150 degrees Celsius
40
350 degrees Celsius
Supervisor or operator correction limit setting
● When the console enters the low temperature alarm limit setting mode, the
hundreds of digits starts to flash. Enter and store the set value in the same way as
described in "Changing the Temperature Settings".
● If the input value exceeds the limit shown on the left, the system will jump back to
the input of the hundred digits. You must re-enter the correct value at this time.
(1.)
(2.)
● Once the value is saved, the system will automatically proceed with the supervisor
or operator correction limit setting.
To change the supervisor or operator correction limit settings, the procedure
is as follows:
● When you enter this mode, the display will show 40 or 41 .
If the card is not inserted, the soldering iron head correction value cannot be input.
If the card is not inserted, you can enter the soldering iron head correction value.
40
41
Press the UP or down button to select the area and press the button. The
system leaves the parameter setting mode and begins to control the heater to be
energized. Normal operation is now possible.