background image

Message       Meaning

Action Required

Sn

Sensors are out of      

If the problem persists,  

balance. If alternating  

contact your dealer or service 

with spa temp, it may 

organization.                  

just be a temporary 
condition.  If flashing by 
itself, spa is shut down.

HL 

A significant difference

Check water level in spa.

between temperature          Refill if necessary. If the water 
sensors has been        

level is okay, make sure the 

detected.  This could

pump(s) have been primed.

indicate a flow problem.                                                                                                                                               

LF

Persistent low flow    

Follow action required for “HL”

problems.  (Displays                             
on the fifth occurrence of 

HL message within 24 hrs.)
Heater is shut down, but
other spa functions continue 
to run normally.

dr

Possible inadequate    

Check water level in spa. If 

water, poor flow or 

water level is okay, make sure

air bubbles detected 

pump(s) have been primed.

in the heater. Spa       

Press any button to reset or this     

is shut down for 15 

message will automatically reset

minutes.

within 15 minutes.                                                                                                                                                                                        

dy

Inadequate water     

Follow action required for “dr” 

detected in heater.   

message.

(Displays on third                      
occurrence of “dr” 
message.) Spa is shut 
down. 

WARNING! / Shock Hazard! / No User Serviceable Parts.

Do not attempt service of this control. Contact Cyanna Valley Spas or service
organization for assistance.  Installation and/or service must be performed by a
licensed electrician and all grounding connections must be properly installed.

13

Summary of Contents for Balboa 100

Page 1: ...2017 Owner s Manual ...

Page 2: ...le pump systems 10 Topside Functions 11 Diagnostic Messages 12 Features found on various Cyanna Valley models 14 Spa Jets and Air Controls 15 Filling Directions Fill the Spa With Water 17 Skimmer Side Filter 18 Add Start Up Chemicals 18 Maintenance 19 Spa Draining 19 Spa Surface Care 20 Long Term Storage 20 Spa Pillow Maintenance 21 Spa Cover Maintenance 22 Filter Cleaning 22 Spa Cabinet Maintenan...

Page 3: ...he suction fittings are broken or miss ing Never replace a suction fitting with one rated less than the flow rate marked on the original fitting 4 DANGER Risk of Accidental Drowning Extreme Caution must be exercised to prevent unauthorized access by children To avoid accidents insure that children cannot use this spa unless they are supervised at all times 5 DANGER Risk of Electric Shock Install a...

Page 4: ...be described as follows Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal temperature of 98 6 F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effects of hyperthermia include Failure to feel heat Failure to recognize the need to exit the spa Unawaren...

Page 5: ...d then return for another stay in the spa INSTALLATION AND SET UP INSTRUCTIONS SURFACE AND PAD REQUIREMENTS Your new portable spa must be placed on a uniformly firm flat and level surface A concrete pad 4 inches thick is best In order to prevent flooding of the electrical equipment the pad must be such that water will drain away from the spa If your spa is located near sprinklers adjust or cap the...

Page 6: ...of the electrical power Plug Play Cord Location For square plug and play spas the GFCI cord can be accessed through the notched corner knockout as shown to the right You may have to remove the equipment access panel and route the cord through the open ing For the round Viking 1P or 2P spas you will need to remove the panel with the cord cutout in the lower left hand section of the panel to access ...

Page 7: ...220 VOLT Balboa 500 Power System 6 Green ground connection located on left side of control panel WHITE BLACK RED GREEN ...

Page 8: ...GFCI WIRING INSTALLATION 220V Balboa 500 Power System 7 ...

Page 9: ...wiring compartment The use of extension cords or improper plug type termination is expressly prohibited and voids the warranty 3 Do not use aluminum wiring Use only copper conductive wiring 4 Wire gauge must be in accordance with NEC requirements for the distance from current source to spa and the current rating as stated on the ID label that is attached to the equipment control enclosure 5 All wi...

Page 10: ... VOID YOUR WARRANTY Please check with a licensed contractor and local codes prior to any con struction OPERATION INSTRUCTIONS 101 pnp 102 pnpX Supreme pnp Supreme pnpX It is very important to make sure that the spa is filled at least 3 4 way up the skimmer opening Make sure the gate valves are in the open or up position WARNING Do not run spa with gate valves closed or run pump with no water circu...

Page 11: ...ure previously set The set temperature flashes on the display Pressing the Temp button a second time while it is still flashing will cause the set temperature to increase or decrease depending on what direction was last chosen Each press to follow will change the set temperature in the same direction If the opposite direc tion is desired release the pad and let the display revert to the actual wat...

Page 12: ...emperature displayed is current only when the pump has been running for at least 2 minutes St will be displayed momentarily when you switch into Standard mode Economy Mode heats the spa to the set temperature only during filter cycles Ec will display solid when temperature is not current and will alternate with temperature when temperature is current Sleep Mode heats the spa to within 20 F 10 C of...

Page 13: ...ically reset 110 F 43 C If it does not shut off the power to the spa and call Cyanna Valley or your service organization IC Ice Potential freeze No action required The pump s condition detected will automatically activate regardless of spa status SA The spa has shut down If the problem persists contact The sensor that is your dealer or service organ plugged into the ization May appear temporari Se...

Page 14: ...24 hrs Heater is shut down but other spa functions continue to run normally dr Possible inadequate Check water level in spa If water poor flow or water level is okay make sure air bubbles detected pump s have been primed in the heater Spa Press any button to reset or this is shut down for 15 message will automatically reset minutes within 15 minutes dy Inadequate water Follow action required for d...

Page 15: ... spa is also incorporated into the light in the foot well of these models The LED Lighting system consists of a 9 position controller The first time the light is turned on it will begin to display all 9 colors available in an automatic rotating sequence Each time you sequence the light on off all colors will be displayed individually The last function of the cycle is a unique strobe feature It may...

Page 16: ... SAME TIME THIS MAY CAUSE DAMAGE TO THE PUMP AND MOTOR Note To remove jet insert turn jet face counter clockwise to the shut off point Continue turning until the jet unscrews from body To reinstall the jet insert jet into body and turn clockwise until the jet stops 15 Twin Adjustable Roto Power Storm Directional Poly Directional Mini Storm Directional Cluster ...

Page 17: ...ain jets back to full power Due to the substantial amount of water pressure when the Turbo Jet is operating you must turn the pump to the off or low speed cycle position before attempting to rotate the jet face AIR CONTROLS Air controls are adjusted by rotating the topside dial These controls serve to regulate the amount of air mixed with water when the whirlpool or hydrotherapy jets are operating...

Page 18: ... the way up the skimmer opening d We DO NOT recommend the use of softened water due to the potential harm of damaging equipment e As water level rises check inside equipment compartments for water leaks It may be necessary to tighten loose unions and or fittings f Make sure T Handled Gate VALVES at pump and heater are open and the valve handle retaining clips are in place Fully extended up positio...

Page 19: ... heating of the spa A starving pump will degrade performance result in dirty or murky water and may cause the heater to malfunction ADD START UP CHEMICALS Ask your local spa retailer to HELP you set up a chemical maintenance program The importance of chemical balance in your spa cannot be overemphasized SANITIZING Please refer to your dealer supplied sanitizing recommen dations for your start up p...

Page 20: ...ap off and attach a garden hose to the opening 2 Turn the outside body counter clockwise until it stops 3 Pull on the drain that the hose is connected to until you hear a pop 4 Drain the spa 5 Reverse this procedure to shut the water off Note the drain will not remove all of the water in the spa You may have to remove a small amount of water by hand DRAIN LOCATIONS Water Gate Valve Drain for 101 p...

Page 21: ...prevent freeze damage to the spa plumbing assembly Remove the piping assembly between the pump and the heater by loosening the union at the pump and the union at the heater Once the piping is removed use a wet dry shop vac to vacuum water from both the pump side and the heater side openings Once all water is removed from these lines we also recommend that you place the vacuum over each jet and the...

Page 22: ...not covered under your warranty FILTER CLEANING 101 pnp 102 pnpX 103 Your filter should be replaced once a year When filters are removed from the spa make sure that no objects fall into the filter cavity They can cause obstruction to water movement Remove filter cartridges as shown in figures below The filter must be cleaned every month more often with heavy use to get rid of objects and particles...

Page 23: ...ing straight up and slightly toward the spa on front plate face cover As shown below Remove access basket and unscrew filter cartridge s from housing To reinstall weir door assembly door must be placed through throat of skimmer prior to sliding assembly into place Refer to filter cleaning procedure for 101 pnp 102 pnpX 103 on previous page Note Spas with this filter utilize 50 sq ft cartridge fil ...

Page 24: ...e recommend the F4 setting which means your spa will filter a total of 8 hours 4 hours twice a day This should provide adequate ozonation provided there is proper chemical balance in the spa NOTE Please Do Not attempt to disassemble ozonator if it becomes inop erable Ozonators contain no user serviceable parts Please contact your spa retailer or service organization GALLON SPECIFICATIONS Model Gal...

Page 25: ...t water add pH Up pH irritation rashes to be corrected pH pH Down Down or Total A as needed allergies total alkalinity Total A Excessive chlorine or Add fresh water and or wait bromine a day re test sanitizer level Excessive foam Build up of body oils Spa Foam Away Add Spa Foam Away to cosmetics and Spa See Clear foamy area then add 1oz contaminants Spa See Clear pH Total Alkalinity Spa See Clear ...

Page 26: ...ation with trapped air Solution Open bleed plug on face of pump and cycle pump to high speed for approximately 30 seconds If not has the spa been drained and refilled Solution Make sure water level three quarters of the way on the skimmer opening Is there proper water flow Solution Make sure both Gate Valves are open and filter is clean Pump Will Not Prime or Function Solution Gate Valves Closed I...

Page 27: ...r hot tub and Avertissement Pour eviter des blessures user de prudence en entrant dans une cuve de relaxation et en sortant Warning Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning and Avertissement Pour eviter l evanouissement et la noyade eventuelle ne prendre ni drogue ni alcool avant d u tiliser une cuve de relaxation ni qu...

Page 28: ...Email cyannavalleyspas gmail com 2017 Cyanna Valley Spas ...

Reviews: