TROUBLE SHOOTING
Caution
: Cyanna Valley Spas have slide type water shut off valves referred
to as Gate Valves. The spa should never be operated with the Gate Valves in
the closed position, as this will cause severe damage to the pump and/or
heater.
Spa Will Not Heat
Check For Air Lock
• Is this a new installation with trapped air?
Solution; Open bleed plug on face of pump and cycle pump to high speed
for approximately 30 seconds.
• If not, has the spa been drained and refilled?
Solution; Make sure water level three quarters of the way on the skimmer
opening.
• Is there proper water flow?
Solution: Make sure both Gate Valves are open and filter is clean.
Pump Will Not Prime or Function
Solution: Gate Valves Closed
Improper wiring to spa
Water level in spa too low
Contact Cyanna Valley Spas or a local service company.
25