35/38
CybTouch 8 P User Manual
S
ep
.
2019
V2.1
M
SG
n
r
.
M
eSSaGe
d
eScripTion
E19
Quantity = 0
When pressing start, the programmed amount of parts to
be made is ‘0’. See
information.
E20
Cycle repeat = 0
Cannot start cycle because repeat cycle function is set to “0”.
E21
E24
Identification Error [ ]
During the Axis Wizard, there was an error identifying one of the
axes. The error number (typically
) gives more
information. See also message
.
E25
No FAST task running [ ]
Switch OFF the machine for 1 min and restart it again.
E26
NULL pointer to axis struct.
This message indicates a software bug. Write it all down and
contact Cybelec.
E27
MUTEX Error [ ]
This message indicates a software bug. Write it all down and
contact Cybelec.
E28
No I/O 24V or overload (output
in safety off)
The 24V power supply for the inputs/outputs is no longer present
or an output is overloaded. Reset any safety device on the
machine, check protection grids and rear guards are closed, etc.
If the problem persists, switch machine OFF for 3 min and restart
it again. If the problem still persists, check the machine manual
and/or ask a service technician to check your machine.
E29
Radio link error, code [ ]
The RFlink chip has detected an error. Check the environment
for disturbances (cell phone, wi-fi) and that the material works
properly. If the problem persists, write the error number down
and send it Cybelec.
E30
Touchscreen error, code [ ]
Please contact your machine dealer with this specific code and
details.
E31
E32
E33
Syntax error in XML file
This file is corrupt and cannot be used. Try to restart the NC. If
the file is a part-program, try to delete it.
E34
Memory allocation problem
(xml)
There was a problem while trying to read a file in the memory.
The file is probably corrupted. The number gives more
information, write it down.
E35
Endless loop on process task
Process error. Please restart the NC and inform your dealer.
E36
“Pedal” input refused
The pedal command is not accepted in this page/situation.
E37
WARNING: Overloop intern
This error should normally never happen on the machine. It
means there are too many elements in a coded list.
E38
Unknown key
There is a list of known screen zones, and the pressed zone is
not in it. This error can normally not happen in the field.
E39
“Start” input refused
The start command is not accepted in this page/situation.
E40
Y smaller than minimum limit
The programed position value for axis Y is below the value of the
minimum limit switch position.
E41
E42
E43
Configuration error
Input/output incorrectly configured in machine parameters, the
faulty input/output page is displayed. Check for unauthorized
doubled outputs or inputs.
This message can also be displayed if the chosen configuration
requires more icons on the first page than there room available.
E44
“External stop” input is active
External stop may be caused by safety devices, emergency
buttons, rear protection guards, etc. See machine instructions.