36/38
S
ept
.
2014
V3.1
CybTouch 8 PS User Manual
M
SG
n
r
.
M
eSSaGe
d
eScripTion
E21
No material defined (define
one or more in MP)
No materials programmed in the Material pages (in User
preferences). A material must be selected to perform
calculations.
E24
Identification Error [ ]
During the Axis Wizard, there was an error identifying one of the
axes. The error number (typically
) gives more
information. See also message
.
E25
No FAST task running [ ]
Switch OFF the machine for 1 min and restart it again.
E26
NULL pointer to axis struct.
This message indicates a software bug. Write it all down and
contact Cybelec.
E27
MUTEX Error [ ]
This message indicates a software bug. Write it all down and
contact Cybelec.
E28
I/O no 24V or overload (output
in safety off)
The 24V power supply for the inputs/outputs is no longer present
or an output is overloaded. Reset any safety device on the
machine, check protection grids and rear guards are closed, etc.
If the problem persists, switch machine OFF for 3 min and restart
it again. If the problem still persists, check the machine manual
and/or ask a service technician to check your machine.
E29
Radio link error, code [ ]
The RFlink chip has detected an error. Check the environment
for disturbances (cell phone, wi-fi) and that the material works
properly. If the problem persists, write the error number down
and send it Cybelec.
E30
Touchscreen error, code [ ]
Please contact your machine dealer with this specific code and
details.
E31
“Crowning” analog input not
configured
While configuring (setting up) the NC, the Crowning dedicated
input was not configured but is requested to run properly.
E32
“Crowning” analog output not
configured
While configuring (setting up) the NC, the Crowning dedicated
outputs were not configured but are requested to run properly.
E33
Syntax error in XML file
This file is corrupt and cannot be used. Try to restart the NC. If
the file is a part-program, try to delete it.
E34
Memory allocation problem
(xml)
There was a problem while trying to read a file in the memory.
The file is probably corrupted. The number gives more
information, write it down.
E35
Endless loop on process task
Process error. Please restart the NC and inform your dealer.
E37
WARNING: Overloop intern
This error should normally never happen on the machine. It
means there are too many elements in a coded list.
E38
Unknown key
There is a list of known screen zones, and the pressed zone is
not in it. This error can normally not happen in the field.
E39
“Start” input refused
The start command is not accepted in this page/situation.
E40
R under minimum limit
The programed position value for axis R is below the value of the
minimum limit switch position.
E41
Thickness smaller than min
The thickness entered for the material is below the minimum
value defined in the User Preferences (see
E42
Thickness greater than max
The thickness entered for the material is above the maximum
value defined in the User Preferences (see
E43
Configuration error
Input/output incorrectly configured in machine parameters, the
error input/output page is displayed. Check for unauthorized
doubled output or inputs.
This message can also be displayed if the chosen configuration
requires more icons on the first page than there room available.
E44
“External stop” input is active
External stop may be caused by safety devices, emergency
buttons, rear protection guards, etc. See machine instructions.