background image

- 14 - 

position.  You can use the Up, Down, Left or Right keys on the keyboard or a mouse to move 

the OSD position.   

  F8: Restore Default Setting; Restore the factory default settings.  Please note that all name lists 

will be cleared and the system settings are set to the default settings as shown in the table above.   

  Esc: Exit; Exit the system setting and close the OSD.  If you have made changes in this option, 

the system will ask whether or not you want to save the setting before the selected option is 

effective.   

  

Auto Scan Mode:

 

You can start the OSD first and press “F4” to enter the Auto Scan Mode.  

If you want to scan the PC, you must use the Smart View Setting to select the Auto Scan Time 

in the System Setting for the residing time, which includes 5 sec, 10 sec, 20 sec, 30 sec and 60 

sec.  You can adjust the Channel Display Mode and Channel Display Time from the Channel 

Display mode.  By then, all keys on the panel, keyboard and mouse are not operable.  You 

can only use the ESC key to exit the Auto Scan Mode. 

  

Security Mode:

 

Switch the Security Level from “None” to “Low” in the System Setting, and 

enter your Password (“A~Z”,“0~9”, a maximum of 12 characters), and the security will be 

effective after you confirm the Password.  The use of the Console Lock Time is to set the 

time to enter a security mode after the keyboard and mouse has idled for a predetermined time.  

Once you enter into the security mode, you need to enter the correct password before you can 

move the mouse or enter any key from the keyboard.  You need a correct password to operate 

the whole system normally.    

       

Important Note:

 What should I do if I forgot my Password?   

After you enter a wrong password for 5 consecutive times, a time delay bar will appear, and a set of 

“Magic Numbers” will show up at the bottom.  Record the magic numbers and contact with your 

distributor. 

EDID

 & DDC: 

A vast majority of computer monitors supports the Extended Display 

Identification Data (EDID) and allows data access by Display Data Channel (DDC).  The KVM 

also supports these two specifications, but the KVM only reads the EDID of the Monitor when 

the KVM is on.  If it is necessary to change monitors during an operation, please use the 

Console Reconfirmed function to read the EDID again.   

F/W U

pdate: 

This product provides a firmware update function.  You can contact your 

distributor for downloading application programs and updated files. Use the F/W Update Cable 

for the update.  Please turn off all PCs before carrying out the update, and do not disconnect the 

power during the update process.   

  Procedure: 

1.  Download and install the application program KVMISP.msi. (Note: This program has to be 

run only in Win98SE, ME, XP or 2000). 

2.  Connect the F/W Update Cable, and the PC end is RS-232 port (COM-X) while the KVM 

end is the updata port.   

3.  Power on the KVM and run KVM-ISP.exe.  Select the COM port. 

4.  Select the Download function and specify to update the KVM-XXXX.KVM file.   

5.  After the update completes (which takes about 1.5 min), power off the KVM.  Unplug the 

F/W Update Cable.  Power on the KVM again. 

6.  You can use the system setting “F1”- Information in the OSD to examine whether or not the 

Summary of Contents for IC-1704

Page 1: ... 1 LCD KVM SWITCH IC 1704 IC 1708 IC 1716 USER MANUAL ...

Page 2: ...ction down or decrease the numeric value parameter in certain menu Auto key Use this key to automatically adjust the image position and phase and return to the previous menu or exit a highlight item If the screen is not in a full screen graphic mode such as in a DOS or is connected with an allocator the position of the appeared image may be adjusted automatically and then deviated By then it is ne...

Page 3: ...ptor You can install a cascade to facilitate expansions or transportation without requiring a cascade cable or changing the KVM configurations On Screen Display OSD Menu The embedded OSD control module lets you name the PC and KVM and modify the KVM configuration and the security mode can prevent others from turning on the KVM by mistake and switching the linked PC from the OSD Most conveniently t...

Page 4: ... easy switch and identification Complies with the height of the 1U chassis specification and installable with a hanging stand into a 19 chassis system Requires no additional software or hardware Supports hot plug not necessary to turn off the original system regardless of a newly installed PC or KVM EQUIPMENT REQUIREMENTS Computer System A Supported VGA SVGA XGA SXGA or Multisync Video Card A PS 2...

Page 5: ...e Touch pad module Console Connector Keyboard Standard 104 key Port Selection Keys on Front Panel 4 8 16 Port 4 8 16 LEDs Power 1 1 1 OSD Built in Video Resolution 1280x1024 75Hz Dimensions 600x450x48 mm Weight 13 3 Kg 13 35 Kg 13 4 Kg Operating Temp 5 40 Storage Temp 20 60 Humidity 10 80 RH non condensing ...

Page 6: ...IC 1716 to open Console Reconfirmed and the keyboard and mouse will be reconnected and the EDID in the screen will be read again 2 Port LEDs These Port LEDs are built in the Port Selection Switches Online A green light indicates that the PC or KVM connected to the corresponding port is on and operating Selected A red light indicates the situation of being connected to the port If a port is connect...

Page 7: ...Rear VIEW IC 1708 Rear VIEW IC 1716 Rear VIEW 1 CPU Port Install the cable connected to a PC here 2 Updata Port The port provides a firmware update function 3 AC Power Jack TheAC Power is applicable for 100 240VAC 50Hz 60Hz 4 Power Switch Power On Off the LCD KVM ...

Page 8: ...el of the Master KVM is OFF Plug one end of the AC power cord to the KVM and the other end to the AC power supply 2 Make sure the power switches at the rear panels of all slave KVMs are OFF Plug one end of the AC power cord to the KVM and the other end to the AC power supply 3 Install the Master KVM to the 3 in 1 cable same as the cable for connecting the KVM to the PC in the middle of the Slave K...

Page 9: ...is OFF Use the AC power cord 3 in 1 cable to connect the console port of the slave KVM to the CPU port of the master KVM Power on the slave KVM For example If you want to install one Slave KVM and three PCs then just follow Step 2 of the foregoing method to add the slave KVM and install the PCs one by one according to Step 1 OPERATION Port Selection The LCD KVM provides fours switching methods Man...

Page 10: ...se the numeric keys to enter the direct switch For example if you want to switch a PC to the Slave KVM port 04 under the Master KVM port 03 then you can start the OSD and then directly enter 0304 If you are using a standalone machine then just enter the first two digits More OSD related information are given in the following OSD sections On Screen Display OSD Start Press the NumLock twice or the P...

Page 11: ...nter Switching F4 Auto Scan F9 System Setting F5 Clear Name List 1 This field provides the information of the currently connected PC As shown in the figure above 03 refers to the Port Number of the Master 04 refers the Port Number of the Slave and Mail Ser 4 is the name of this PC defined by Users If a PC connects to the Master then the number consists of the first two digits If a User has not giv...

Page 12: ... operating the Hot Key Switch or Mouse Clicking or selecting the option by Auto Scan You also can use mouse to click this field Selection BAR It shows the selection bar Green you can use the keys on the board to move the selection bar and the situated position indicates the selected target for giving instructions For example if the selection bar points at C 05 and you press Enter then the system w...

Page 13: ...eys of the OSD control screen NumLock Scroll Lock Shift None Hot Key Switching Turn on off the Ctrl hot keys on the keyboard for switching computer functions OFF ON Mouse Clicking Turn on off the keys of the mouse for switching computer functions OFF ON Beeper Sound Turn on off the beeper sound function ON OFF Offline Skip Set the offline skip function to auto or manual Manual Auto OSD Language Se...

Page 14: ...e mouse or enter any key from the keyboard Youneed a correct password to operate the whole system normally Important Note What should I do if I forgot my Password After you enter a wrong password for 5 consecutive times a time delay bar will appear and a set of Magic Numbers will show up at the bottom Record the magic numbers and contact with your distributor EDID DDC A vast majority of computer m...

Page 15: ...pecial cable of the KVM switch and then power on the KVM switch Connect the special cable of the KVM switch and power on the PC A3b If the KVM switch is connected in series then power off the PC Unplug the special cable of the KVM switch Power on the master KVM switch and then start the slave KVM switch Connect the special cable to the KVM switch and power on the PC Q4 What should we do if there i...

Page 16: ... 16 ...