background image

 

EN   

 
 
 

 

 

 

 

 

 
 
 
 
 

 

CP900/1300/1500EPFCLCD 

User’s Manual 

 

K01-0000460-00

 

 

 

This manual contains important safety instructions. Please read and follow all instructions carefully during 
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or 
operate your UPS. 

CAUTION! 

The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker 

protection. 

DO NOT

 plug the UPS into an outlet that is not grounded. If you need to de-energize this 

equipment, turn off and unplug the UPS. 

CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! 

CyberPower Systems does 

not sell products for life support or medical applications. 

DO NOT

 use in any circumstance that would affect 

the operation and safety of life support equipment, medical applications, or patient care. 

CAUTION! 

Hazardous live parts inside can be energized by the battery even when the AC input power is 

disconnected. 

CAUTION! 

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor 

area, free of conductive contaminants. (Please see specifications for acceptable temperature and humidity 
range). 

CAUTION! 

To reduce the risk of electric shock, do not remove the cover, except to service the battery. There 

are no user serviceable parts inside, except for the battery. 

CAUTION! 

To avoid electrical shock, turn off the unit and unplug it from the AC power source before 

servicing the battery or installing a computer component. 

CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! 

To reduce the risk of fire, do not use with or near 

aquariums. Condensation from the aquarium can come in contact with metal electrical contacts and cause 
the machine to short out. 

DO NOT USE THE UPS ON ANY TRANSPORTATION!

    To reduce the risk of fire or electric shock, do not 

use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during 
transit and the damp environment can cause the unit to short out. 

 

 

 

 

UNPACKING 

The box should contain the following: 
(1) UPS Unit x 1; (2) Telephone Cable x 1; (3) USB Cable x 1; (4) User Manual x 1; (5) Management software 
Disk x 1; (6) Function Setup Guide x 1 ; (7) Power Cord (Type and quantity may differ from models.) 
 

OVERVIEW

 

The CP900/1300/1500EPFCLCD provides automatic voltage regulation for inconsistent utility power. The 
CP900/1300/1500EPFCLCD features 405 Joules of surge protection, and provides battery backup during 
power outages. The CP900/1300/1500EPFCLCD ensures consistent power to your computer system and its 
included software will automatically save your open files and shut down your computer system during a utility 
power loss. 
 

SUPPORTS Active PFC POWER SUPPLIES 

This CyberPower UPS system supports High Efficiency power supplies with Active Power Factor Correction 
(Active PFC). Active PFC is used to improve the efficiency of power delivery. The current US Energy Star®  
Program Requirements for Computers (version 5.0) mandates Active PFC for all power supplies over 100 
watts. Additionally, programs such as 80 Plus®  are often used to identify high efficiency power supplies with 
Active PFC. 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

1.  Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral 

equipment does not exceed the 900VA/1300VA/1500VA. 

2.  Ensure that the equipment plugged into the battery power-supplied/surge outlets does not exceed the 

UPS unit's rated capacity (

900VA/540W for CP900EPFCLCD

, 1300VA/780W for CP1300EPFCLCD, 

1500VA/900W for CP1500EPFCLCD). If the rated unit capacities are exceeded, an overload condition 
may occur and cause the UPS unit to shut down or the circuit breaker to trip. 

 

 

 

 

  DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.  Power Switch 

Used as the master on/off switch for equipment connected to the battery power supplied outlets.

 

2.  Power On Indicator 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of 
surges and spikes. 

3.  LCD Module Display 

High resolution and intelligent LCD display shows all the UPS information with icons and messages. For 
more information, please check the 

“Definitions for Illuminated LCD Indicators” section. 

4.  Display Switch 

The switch can be used to select the LCD display contents including Input Voltage, Output Voltage and 
Estimated Run Time. The toggle frequency is set to one time per 0.5 second. Press the switch to roll 
down the function menu. Pressing the switch for 2 seconds will turn the LCD display on or off while in 
AC/Utility power mode. 

5.  Silence Alarm Switch 

The toggle frequency is set to one time per 0.5 second. Press the switch to roll up the function menu. 
Holding the switch for more than 2 seconds will silence the buzzer. 

6.  Control Switch 

Press the Control switch for 3 seconds in AC/Utility Power Mode to perform a Self Test of the battery. 

7.  USB Charging Ports 

The USB Power ports provide 5V 2.1A power output. 

8.  Communication Protection Ports RJ11/RJ45 

Communication protection ports will protect any standard modem, fax, telephone line, or network cable 
from surge and spikes. 

9.  USB Port to PC 

This port allows connection and

 

communication from the USB port on the computer to the UPS unit. The 

UPS communicates its status to the

 PowerPanel

®

 Personal Edition

 software. 

10. Serial Port to PC 

This port allows connection and communicates from the DB-9 serial on the computer to the UPS unit. 
The UPS communicates its status to the PowerPanel®  Personal Edition software. 

NOTE:

 Only one of these two ports can be used as communication and control of the UPS unit at one 

time. 

11. Battery and Surge Protected Outlets 

The unit has several battery powered/surge suppression outlets for connected equipment to ensure 
temporary uninterrupted operation of your equipment during a power failure. Check the type and quantity 
of outlets for different models in the following table. 

(DO NOT plug a laser printer, paper shredder, 

copier, space heater, vacuum, sump pump or other large electrical devices into the 

“Battery and 

Surge Protected Outlets

”. The power demands of these devices may overload and damage the 

unit.) 
 

Model 

NEMA 

DE 

UK 

AU 

FR 

Outlet 

Type 

 

 

 

 

 

 

 

Quantity 

 

12. Circuit Breaker 

Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection. 

13. AC Input 

Connect the AC Power cord to a properly wired and grounded outlet. 

 

 
 

 

1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 

hours is recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss 
may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC 
outlet. The unit will charge in both the on and off position. 
Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment. 
The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up. 

2. If you will use the software, connect the USB cable to the USB port on the UPS. 
3. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data 

storage device (Zip drive, Jazz drive, Tape drive, etc. )into the battery power supplied outlets. 

DO NOT

 

plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the 
battery power supplied outlets. The power demands of these devices will overload and possibly damage 
the unit. 

4. To protect a fax, telephone, modem line or network cable, connect a telephone cable or network cable 

from the wall jack outlet to the IN jack of the UPS. Then connect a telephone cable or network cable from 
the OUT jack on the UPS to the modem, computer, telephone, fax machine, or network device. 

5. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is 

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. 
air conditioner, refrigerator, copier, etc. Avoid using extension cords. 

6. Depress the power switch to turn the unit on. The power on indicator light will illuminate and the unit will 

"beep". 

7. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, 

turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 
10 seconds. Make sure the circuit breaker is depressed and then turn the UPS on. 

8. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the 

battery will automatically recharge. 

9. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
10.To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the 

battery every three months to ensure battery life. 

 

 

 

 

CyberPower’s Green Commitment

 

CyberPower is dedicated to the development of green products, and has adopted   
Green practices throughout its business, including: membership in Climate Savers   
Computing Initiative (CSCI), accordance with the Restriction on Hazardous   
Substances (RoHS), Waste Electrical and Electronic Equipment (WEEE) protocols,   
as well as ISO 14001 and IECQ QC080000. CyberPower pledges to provide the   
advanced energy solution for the environment and become a leading eco-friendly   
organization in the UPS industry. 
 

Reduce Energy Cost with GreenPower UPS

TM

 Technology 

CyberPower’s goal is not only to provide eco-friendly products but also to bring the best value for consumers.

 

The advanced energy-saving design improves the operating efficiency and eliminates waste energy 
consumption

.

 As a result, consumers will enjoy significant energy cost savings with the adoption of

 

GreenPower UPS

TM

 

technology. 

 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

IMPORTANT SAFETY INSTRUCTIONS 

HARDWARE INSTALLATION GUIDE 

CYBERPOWER GREENPOWER UPS™ TECHNOLOGY 

 

CP900EPFCLCD 

CP1300/1500EPFCLCD 

Reviews: