Recommended setting:
10A for 100Ah battery
15A for 150Ah battery
20A for 200Ah battery
Page 10
– Auto Restart Voltage
CPD1200EO12LCD:
Any/10.5/11.0//11.5/12
.0/12.5/13.0/FUL/ESC
CPD2200EO24LCD:
Any/21.0/22.0/23.0/24.
0/25.0/26.0/FUL/ESC
Any
When the utility power
comes back and starts to
charge the battery, the
Power Inverter will auto
restart at the setting battery
voltage.
Page 11
– Low Battery Shutdown
Voltage
CPD1200EO12LCD:
10.0/10.2/10.4/10.6/10.
8/11.0V/ ESC
CPD2200EO24LCD:
20.0/20.4/20.8/21.2/21.
6/22.0V/ ESC
1200VA:
10.0V
2200VA:
20.0V
The Power Inverter will shut
off if the battery voltage is
decreasing to the setting
value.
Page 12
– LCD Auto Sleep
Off
0.5/1/2 Min
ESC
1 Min
If Auto Sleep is selected, the
LCD display will shut off after
0.5/1/2 minutes if no activity.
Page 13
– Cycling Display
Off
0.5/1 Min
ESC
0.5 Min
If the buttons are not
touched in 0.5/1 minute, the
LCD will start cycling the
Inverter information.
Page 14
– Setup $/kwh
0.00 ~ 999
ESC
0.00
Setup the electricity tariff by
kwh. The unit will count and
show how much money
saved from PV power.