4.Setup (Output Voltage, Frequency, SPF Mode, and Saving Mode)
4.1 Initial State
The initial state of inverter is 120Vac/60Hz or 230Vac/50Hz. If users need to adjust for
certain application, configuration can be done through the setting button on the front
panel (Please refer to section 4.2). The unit will restart automatically once the setting is
completed and new settings will be activated. These new settings will be remained even
when the unit is power on/off for any reason.
4.2 Procedure of Setting Output Voltage, Frequency, SPF Mode, and Saving Mode
During Solar Power First (SPF) mode, the off-grid inverter will take battery power as the
primary source and utility as the secondary. When the battery is dried up, the inverter
will switch to utility and solar charger start working by consuming solar energy for battery
charging. Once the battery is fully charged, the inverter will then switch back to battery input.
STEP 1 :
Before setting, the inverter should be turned off and the input batteries should
remain connected. AC main can either be connected or disconnected, and the
loads should be removed..
STEP 2 :
Use an insulated stick to press the setting button then turn on the power switch.
After pressing the setting button for 5 seconds, the inverter will send out a
"Beep" sound. Users can then release the button and proceed to the setting
procedure.
EN
11
Summary of Contents for CPS1000
Page 1: ...OFF GRID INVERTER Instruction Manual CPS3000 CPS1500 CPS1000 CPS400 ...
Page 9: ...CPS3000SAxx CPS1500SAxx CPS1000SAxx CPS400SAxx EN 6 ...
Page 10: ...CPS3000ESAxx CPS1500ESAxx CPS1000ESAxx CPS400ESAxx EN 7 ...
Page 24: ...FR ONDULEUR HORS RESEAU Manuel d instructions CPS3000 CPS1500 CPS1000 CPS400 ...
Page 30: ...CPS3000SAxx CPS1500SAxx CPS1000SAxx CPS400SAxx FR 27 ...
Page 31: ...CPS3000ESAxx CPS1500ESAxx CPS1000ESAxx CPS400ESAxx FR 28 ...
Page 45: ...Note ...
Page 46: ...Note ...
Page 47: ...Note ...