Operation Modes
There are three types of modes regarding to the operation of the Power Inverter. The corresbonding
LCD displays are as shown below.
LCD Display
Operation Mode
Standby Mode(only AC)
In this Mode, the Inverter is off and the Utility power
bypasses to output and in the meantime charges the
battery. The LCD is on to show battery status.
Standby Mode(only PV)
In this Mode, the Inverter is off and the solar power
charges the battery. The LCD is on to show battery status.
Standby Mode(both PV and AC)
In this Mode, the Inverter is off and the Utility power
bypasses to output and the battery is charged by both AC
and PV. The LCD is on to show battery status.
Line Mode1
The Power Inverter is turned on and AC input power is
normal. It supplies power to the load (connected
equipment).
Line Mode2
The Power Inverter is turned on and AC input power is
normal. It supplies power to the load (connected
equipment) and PV power charges the battery in the
meantime.
Summary of Contents for CPS1200EO12LCD