13
Battery Mode1
During a severe brownout or blackout, the Utility Power is
absent and the Power Inverter switches to Battery Mode.
The battery will supply power to the load (connected
equipment).
Battery Mode2
During a severe brownout or blackout, the Utility Power is
absent and the Power Inverter switches to Battery Mode.
The battery and PV panels will supply power to the load
(connected equipment).
4 OPERATION & CONFIGURATION
Power On/Off
Power On
:
Press the
POWER
button to turn on the unit.
Power Off
:
Press the
POWER
button again to turn off the unit.
Function Setup
Press the
SETUP
button for 4 seconds
to access the setup mode’s 7 functions:
Audible Alarm, Auto
Restart Voltage, Low Battery Shutdown Voltage, LCD Auto Sleep, Cycling Display, Back to Default,
and Return to Status Display
. Short press the
SELECT
button to view the functions. When a function is
selected, short press the
SETUP
button to access the function
’s options. Short press
SELECT
button
to view the options. When the desired option is selected, short press
SETUP
button to confirm the
setting. The unit will leave Setup Mode if there is no operation in 60 seconds.
Audible Alarm
Press
SELECT
button for 2 seconds to enable the audible alarm (beeps once) or disable (beeps twice)
the audible alarm. The MUTE icon will appear on the LCD display when the audible alarm is disabled.
Function Setup Guide
Function
Options
Default
Description
Page 1 - Audible Alarm
On
Off
ESC
On
If Off is selected, the unit will
mute alarms and the Mute
icon will appear on the LCD
display.
Summary of Contents for CPS1200EO12LCD
Page 1: ...Hybrid Inverter CPS1200EO12LCD CPS2200EO24LCD User s Manual ...
Page 2: ...2 ...
Page 24: ......