16
setting voltage point in P05,
unit will transfer back to PV
mode.
Page 6
– Auto Restart Voltage
CPS1200EO12L
CD:
Any/10.5/11.0/
/11.5/12.0/12.5/
13.0/FUL
CPS2200EO24L
CD:
Any/21.0/22.0
/23.0/24.0/25.0
/26.0/FUL
ESC
Any
When the utility power
comes back and starts to
charge the battery, the
Power Inverter will auto
restart at the setting battery
voltage.
Page 7
– Low Battery Shutdown
Voltage
CPS1200EOLC
D:
10.0
/10.2/10.4
/10.6/10.8/11.0V
CPS2200EO24L
CD:
20.0
/20.4/20.8
/21.2/21.6/22.0V
ESC
10.0V
(20.0V for
CPS2200
EO24LCD
)
The Power Inverter will shut
off if the battery voltage is
decreasing to the setting
value.
Page 8
– LCD Auto Sleep
Off
0.5/1/2 Min
ESC
1 Min
If Auto Sleep is selected, the
LCD display will shut off after
0.5/1/2 minutes if no activity.
Summary of Contents for CPS1200EO12LCD
Page 1: ...Hybrid Inverter CPS1200EO12LCD CPS2200EO24LCD User s Manual ...
Page 2: ...2 ...
Page 24: ......