17
6.3 LCD Display description
In the first line of the LCD, it displays the warning error code & current status & setting item.
The current status includes Normal, Warn, and Error. More info about error & warning code
and setting item please refer to following pages. In the second line of the LCD, it displays input
& output parameters and time of inverter
Table 6-4
Items
Description
Vb/Cb: xx.xV/ xxx%
Battery Voltage/Battery Capacity
Vpv: xxxV/ xxxV
PV Voltage
:
PVA Voltage/PVB Voltage
Ic_pv: xx.x / xx.x A
PV Charge Current: PVA Charge Current/ PVB Charge Current
Ppv: xxxx/ xxxxW
PV Charge Power: PVA Charge Power/ PVB Charge Power
AC_In: xxxV/ xxHz
Voltage/Frequency of input AC
AC_Out: xxxV/ xxHz
Voltage/Frequency of output AC
Ichr_ac: xx.xA
AC Charge Current
Ichr_all: xxx.xA
Max. Charge Current
PL: xxxxW/ xxxxVA
Power of Load
Per_Load: xxx%
Load Percentage
Epv_d: xxxx.x KWh
Daily PV Generation
Epv_a: xxxx.x KWh
Total PV Generation
Ec_d: xxxx.x KWh
Daily Charged Capacity of Battery
Ec_a: xxxx.x KWh
Total Charged Capacity of Battery
Ed_d: xxxx.x KWh
Daily Discharged Capacity of Battery
Ed_a: xxxx.x KWh
Total Discharged Capacity of Battery
20xx/xx/xx xx:xx
Time
SerNo: xxxxxxxxxx
Series Number
FW Version: xxxx
Firmware Version