Without PV power,
1.
Disconnect unit Grid O/P plug.
2.
Press and hold the button until all LEDs are green in order to wake up unit, (takes about 1-2s), and
then release the button immediately.
3.
Wait until the Battery LED in ON, and the others are OFF.
4.
Press and hold the button again until Off-Grid LED is flashing, (takes around 3s), and then release
the button immediately.
5.
The unit supplies power to Standalone O/P outlet if the battery voltage is higher than 22V.
PV Module
Electrical Grid
Appliances
(Emergency usage)
Multiple charge, 5V/2A
(2A max for each USB and total)
CPSHB300ETR-IN
Optional external battery
VRLA, 24V (12V*2)
DC
AC
USB
X
Fig. 7-2 Power flow of Off-Grid operation
7.4 Shut-down the Unit
1.
If unit is operating, press and hold the button until all LEDs are red, it takes around 3 seconds.
2.
Disconnect the AC/Grid power cord.
3.
Disconnect all PV connectors.
4.
When all LEDs are OFF, the unit will totally shutdown.