background image

INTELLIGENT UPS SERIES

OR500LCDRM1U / OR700LCDRM1U

USER MANUAL

YOUR ULTIMATE ALLY IN POWER

Cyber Power Systems (USA), Inc.

4241 12th Avenue East, Suite 400  |  Shakopee, MN 55379  |  

CyberPowerSystems.com

FEATURES

1.  LCD Module Display
2.   Power On Indicator
3.   Power Switch
4.  LCD Function Selected Switch
5.   Battery and Surge Protected Outlets 
6.   Full-Time Surge Protection Outlets
7.  SNMP / HTTP Network Slot

8.   Communication Protection Ports RJ45
9.  USB Port to PC
10.  Dry Contact
11.   Circuit Breaker
12.  AC Input
13.  Electrical Wiring Fault Indicator (Red)

Summary of Contents for OR500LCDRM1U

Page 1: ...379 CyberPowerSystems com FEATURES 1 LCD Module Display 2 Power On Indicator 3 Power Switch 4 LCD Function Selected Switch 5 Battery and Surge Protected Outlets 6 Full Time Surge Protection Outlets 7 SNMP HTTP Network Slot 8 Communication Protection Ports RJ45 9 USB Port to PC 10 Dry Contact 11 Circuit Breaker 12 AC Input 13 Electrical Wiring Fault Indicator Red ...

Page 2: ...lling a computer component CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 CAUTION Do not dispose of batterie...

Page 3: ...or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your electronic equipment will require For optimal system performance keep the load below 80 of the unit s rated capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However after receiving a new UPS to ensure the battery s maximum charge capacity it is recommended t...

Page 4: ...re DO NOT plug a laser printer paper shredder copier space heater vacuum cleaner sump pump or other large electrical devices into the Battery and Surge Protected Outlets The power demands of these devices may overload and damage the unit 6 Full Time Surge Protection Outlets The unit has two surge suppression outlets 7 SNMP HTTP Network Slot Remove the cover panel to install an optional RMCARD prov...

Page 5: ... 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 DO NOT lay tools or other metal parts on top of battery or any battery terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock ...

Page 6: ...V 3rd V X X X V V 4th V X X V X V 5th Return V X X V X V Overload V X V Select SW Press UPS Status Display Capacity Display Digital Value Display Load Cap Battery Cap Input Voltage Output Voltage of Load of Batt Run Time Initial X V X X V V 1st X V X X V V 2nd X V X V X V 3rd X V X X V V 4th X V X X V V 5th Return X V X X V V Overload X V V Line Mode Battery Mode V Illuminated X Not Illuminated Ei...

Page 7: ...t CyberPower Systems about replacement batteries at cyberpowersystems com support The UPS will not turn on The on off switch is designed to prevent damage from rapidly turning it off and on Turn the UPS off Wait 10 seconds and then turn the UPS on The battery is worn out Contact CyberPower Systems about replacement batteries at cyberpowersystems com support Mechanical problem Contact CyberPower Sy...

Page 8: ...NON CONDENSING Size W x H x D 433 x 235 x 44 mm 1U Rack 17 05 x 9 25 x 1 75 in Net Weight 16 5 lbs 7 47 kg 17 3 lbs 7 83 kg Battery Type CyberPower RB0670X2 CyberPower RB0690X2 Typical Battery Recharge Time 8 hours Typical Battery Life 3 to 6 years depending on number of discharge recharge cycles Recommended Battery Sealed Maintenance Free Lead Acid Battery Safety Approvals UL1778 4th cUL CSA C22 ...

Page 9: ...ur state This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of ...

Reviews: