Fault Finding
In the event of cabinet fault/failure, please check the following:
1. Plug is in socket and power to the socket can be proven by plugging another appliance
into the same socket or swapping the problem cabinet to a socket that is known to
work.
2. The condenser is clean and free from dust or debris.
3. Door gasket is sealing and free from damage.
4. Check if the evaporator is iced up, if found to be iced up push and hold
to start
manual defrost.
If this
doesn’t solve the problem, please call CyberChill on 1300 072 000.
When requesting a service call, please find the manufacturers data plate and provide the
model, serial number and details of any fault codes that are displayed.
Alarms
The controller is equipped with visual and audio alarms:
Alarm
Displayed
Description
Action Required
do
Door Open Alarm
Close door
hc
Condenser High Temperature Alarm Check for blockage / clean
hi
High Temperature Alarm
Press a button to cancel / check
Lo
Low Temperature Alarm
Press a button to cancel / check
E1
Probe T1 Failure
Call Engineer
E2
Probe T2 Failure
Call Engineer
E3
Probe T3 Failure
Call Engineer
OFF
Cabinet In Standby
Press
for 3 seconds
Press any button on the controller to silence an alarm.