background image

 

 

 
 
 
 
Commissioning Instructions

 

 

Refrige1

o

C to +4

o

C

 

 

 

Temperature Setting

 

 

Refrigerators are designed to operate b1

o

C and +4

o

C depending on the model. 

The  control  is  preset  at  the  factory  for  this  temperature  and  should  require  no 
readjustment.  

 

The  temperature  setting  can  be  checked  by  unlocking  the  controller  by  pressing  the 

centre  key  twice 

.  Once  unlocked  press the  centre  key  again  to  display  SP,  press 

the centre key again to display the set point.This setting can then be changed to better 

meet site conditions by pressing the 

 or 

 buttons. (Refrigerators have a maximum 

setting  of  10

o

C  and  a  minimum  of  -2C.)  The  temperature  set  is  the  cut  out  (stopping) 

temperature; the cut-in

 

(starting) temperature is determined by the differential. 

 

 

Defrosting

 

 

All  CyberChill  refrigerated  cabinets  are  fitted  with  a  fully  automated  defrost  system  that 
ensures  the  cooling  system  remains  free  from  ice  under  normal  conditions.  If  a  manual 

defrost  is  required,  this  can  be  activated  by  pressing

 

,  for  2  seconds  which  will 

terminate  automatically  once  the  pre-programmed  temperature  has  been  reached.

Summary of Contents for CCB 550

Page 1: ... 1 OPERATING INSTRUCTIONS CCB CCT 550 Glass Door Merchandiser V2 2017 CyberChill Refrigeration P O Box 7200 Baulkham Hills BC NSW 2153 Australia 1300 072 000 www cyberchill com au ...

Page 2: ...This page is intentionally left blank ...

Page 3: ...acement 5 Replacing the LED Tube 5 Removing Cassette Bottom Mount 6 Removing Casette Top Mount 7 Initial Start Up 8 Checks 8 Using Your New Piece of Refrigeration Equipment 8 Commissioning Instructions 9 Fault Finding 10 Alarms 11 LAE Controller Wiring Diagrams 12 Notes 13 Contents All information is subject to change without prior notice ...

Page 4: ...s back and not its side or front to avoid damage When lowering or raising the cabinet extreme care should be taken as the casters can cause the cabinet to slip away whilst lifting or lowering A person should always be standing at the base of the cabinet whilst it is being lowered or raised Cabinet should not be plugged in for at least 1 hour if it has been laid down or tipped during installation T...

Page 5: ...ED Light Tube The cabinet has one interior side light The side light houses one 12 Watt T5 LED tube which may be replaced without removing shelves or product from the cabinet 1 Disconnect the cabinet from the mains power supply 2 Slide a thin flat head screw driver between the diffuser and the edge its clipped into Remove the side light diffuser by sliding the screw driver down the full length of ...

Page 6: ...fig 1 3 Lower the kick panel to remove and set aside fig 2 4 Using a flat head screw driver undo the 4 screws on the control fascia and remove fig 3 5 Using a Phillips head screw driver undo the outermost crews securing the lifting handles fig 4 6 Unplug the 4 plugs leading into the electrical compartment fig 5 7 Lower the handles to drop the cassette down and slide out to perform work fig 6 Fig 1...

Page 7: ... recommended to avoid causing damage fig 2 4 Unplug the 4 plugs into the electrical compartment fig 3 5 Undo the 2 bolts holding the cassette on to the cabinet with a number 13 spanner fig 4 6 The cassette can now be lifted off the cabinet 7 Should works only be required on the evaporator housing proceed with steps 1 2 3 4 and Then 8 8 Undo the 4 bolts holding the insulated lid set aside and proce...

Page 8: ...rmits stay with the cabinet until the pre set temperature is reached and the condensing unit cuts out Using Your New Refrigeration Equipment The cabinet must reach its preset operating temperature before loading any produce Ensure stored products are evenly distributed on shelves ensuring that no more than 40kg are placed on each shelf Cover all foods ensuring that cooked and raw foods are kept se...

Page 9: ...ay the set point This setting can then be changed to better meet site conditions by pressing the or buttons Refrigerators have a maximum setting of 10oC and a minimum of 2C The temperature set is the cut out stopping temperature the cut in starting temperature is determined by the differential Defrosting All CyberChill refrigerated cabinets are fitted with a fully automated defrost system that ens...

Page 10: ...l CyberChill on 1300 072 000 When requesting a service call please find the manufacturers data plate and provide the model serial number and details of any fault codes that are displayed Alarms The controller is equipped with visual and audio alarms Alarm Displayed Description Action Required do Door Open Alarm Close door hc Condenser High Temperature Alarm Check for blockage clean hi High Tempera...

Page 11: ...Wiring Diagram ...

Page 12: ...Notes ...

Page 13: ...34a 1430 R404a 3922 These units contain fluorinated greenhouse gases covered by the F Gas directive Declaration of Conformity References Low Voltage Directive 2006 95 EC EC Machinery Directive 2006 42EC Electromagnetic Compatibility Directive 2004 108 EC Pressure Equipment Directive 97 23 EC RoHS WEE Directive 2002 95 EC ...